RISCO Group GT490X User Manual
Page 11

The display will then show:-
5. Select either 1 or 2 depending on which standard you require.
The display will show:-
6. Enter Engineer code.
(1234 default). The display will show:-
7. Enter the Authorisor code. The Authorisor code is the Master User, (default 5678).
The display will show:-
8. Press Yes. The display will show:-
From this point the panel is Engineer Mode and all Tampers will be disabled.
Note:
At any point when three underscores are shown on the display you are
viewing a Header. You may move to the next Header by Pressing the NO
Key or access the functions under the Header by pressing the YES Key.
You are able to jump to various common options when programming by
entering the relevant menu numbers. With a Header showing, key in the
appropriate menu number, then press Yes.
Page 10
Do you want to . .
Use ENGNR. Mode ?
Enter Authorisor
Code . . . . . .
Program . . . .
- - -
Zones ?
A Header is indicated by three
underscores on the display.
Select 1: PD2004
2: PD2010
01 Jan 00: 00: 01