Keypad disabled for 90 seconds.
The keypad will monitor the number of attempts without a valid User Code being
entered. More than seven attempts will cause a keypad tamper and lock-out the
keypad for 90 seconds. This will be displayed as ‘LOCK-OUT Check’ and will require
a valid User Code entry to stop the sounders (only after 90 seconds). If the system
was Unset only the internal sounders will operate. If the system was Set a full alarm
will be generated.
Setting by digital key
Setting the system must be initiated from within the premises; when using a radio
fob interaction with the keypad will be required.
Setting the system with a Gtag fob must be from a keypad (not from a remote
setting point) to comply with the standards for monitored alarms.
Zones on soak test.
Zones that are put on test must be indicated to the user. When setting the system
the user must acknowledge this by pressing No.
Entry Procedure
As per BS8243 - 2010, Annex G.
A confirmed alarm may now be generated on entry by straying off from the entry
route into a normal alarm zone.
Engineer on site channel.
BS-EN50131 - 3 2006 plus A1 2009, as per 8.3.1.
When an Engineer code is entered a signal is sent to the ARC indicating an
engineer is on site.
New Fast format channels.
Engineer on site. PA Confirm
New Contact ID and SIA triggers.
Engineer on site = Off/On.
New option for the reset modes.
Fault Reset = +Anti / Eng code / Anti code.