7

1 Open the safety cover
- See Chapter 7.1

2 Remove the safety glass
- At one of the retaining pins located

on the side, carefully insert a
screwdriver between the safety glass
and the cover.

- Lift the safety glass up and over the

retaining pin and remove it to the
side.

Fig. 3: Remove the safety glass

3 Insert new safety glass
- Push the safety glass under one of

the retaining pins located on the side
and press it under the retaining pin
on the other side.

- Close the safety cover and tighten

the screws making sure the seal sits
correctly.

9.3. Replacing the halogen lamp

CAUTION:
Do not touch halogen lamps with bare
hands.

WARNING: Risk to life and limb

from electric shock
Disconnect the earthed plug from the
mains socket before all cleaning or
servicing work.

WARNING: Risk of burning

Allow the portable spotlight to cool off for
at least 20 minutes after switching off.
Only then may it be touched.

1 Open the safety cover
- See Chapter 7.1

2 Remove the old halogen lamp

3 Insert the new halogen lamp
- Take the halogen lamp out of its

packaging. Do not touch the halogen
lamp under any circumstances with
bare hands. Use a cloth or
something similar to hold the
halogen lamp.

- First insert one side of the halogen

lamp into the socket. When doing so
the pin will be pressed inwards.

- Then insert the other side of the

halogen lamp into the socket.

- Close the safety cover and tighten

the screws making sure the seal sits
correctly.

9.4. Replacing the mains cable

WARNING: Risk to life and limb

from electric shock

Damaged mains cable

If damaged, the mains cable on the
portable spotlight must be replaced by the
manufacturer, by a manufacturer's service
technician or by a comparably qualified
person.

10. Disposal

INFORMATION: The packaging

and the packaging material is made from
environmentally friendly materials and can
be 100 % recycled.

It is not permissible to dispose
of the product with normal
household waste at the end of
its service life. Ask your local
authorities where to dispose

of the device in an environmentally-
friendly and correct manner.