7. Remove outside mounting plate with tube attached from wall.

Mark and cut the extra length of the 6 5/8” (168 mm) diameter

tube from the opposite end. Do not crimp or enlarge tube.

8. Attach the 4” (102 mm) diameter flue outlet tube onto the rigid

venting system or directly to fireplace. Ensure the 4” (102 mm)

diameter flue outlet tube is placed as far as possible onto the

rigid venting system. Mark the 4” (102 mm) diameter flue outlet

tube 2 1/2” (64 mm) beyond the vinyl siding kit or wall. See

Figure 49. Remove the 4” (102 mm) diameter flue outlet tube

from rigid venting system. When installing directly to fireplace,

tape gasket needs to be used.

9. Mark or wrap tape completely around the tubes at the marked

points to help in making a true cut. Do not crimp or enlarge

tubes.

10. From outside: Push the 6 5/8” (168 mm) diameter inlet tube/

mounting plate onto end of rigid venting system to correct posi-

tion. Fasten the outside mounting plate to the vinyl siding kit or

wall with (4) 10 x 1 1/2” screws. (Ensure upward slope).

11. From inside: Attach the inlet tube to the collar on the back of

the fireplace (or the rigid venting system) using (3) self tapping

screws.

12. Seal the 4” (102 mm) diameter flue outlet tube. Follow instruc-

tions and diagram (Figure 50).

13. Fasten 4” (102 mm) diameter flue outlet tube in place. Do not

“twist” the flue outlet tube into the fireplace collar (or rigid

venting system). Hold the tube by the seam and push in using

a perpendicular “rocking” motion. This ensures the seam on the

tube stay intact.

14. Fasten vent cap end using (3) 10 x 1/2” screws to mounting

plate. Sealing 4” (102 mm) Diameter Flue Outlet Tube

OUTSIDE WALL

MEASURE

VINYL SIDING KIT DV822

OUTSIDE MOUNTING

PLATE

EXT. WALL
SURFACE OR
VINYL SIDING KIT

FLUE
PIPE

CUT

2 ½”

BEYOND EXTERNAL

WALL SURFACE OR

VINYL SIDING KIT

Figure 48

Figure 49

1”

VENT CAP END

APPLY SEALANT

ON THE INSIDE

DO NOT PLACE

OVERLAPPED

SECTION OVER

THE SEAM IN THE TUBE

Figure 50

Note: Tape gasket to be applied prior to installing to fireplace flue outlet tube

only. Tape gasket should not be used when mating the flue outlet tube to a rigid

venting system.