Fig.1a fig.1b, Introduction & specifications, Preparation – Sealey SSC12710 User Manual
Page 3

2. INTROdUCTION & SPECIFICATIONS
High performance, top of the range screw compressors offer high
continuous output of air with low running costs. one of the most
economical ways to get compressed air 24/7 with minimal downtime.
Very few moving parts means servicing/maintenance will be less
frequent and less expensive compared to an equivalent piston
compressor. Insulated class f 10hp motor with IP54 protected
control box which is easy to operate with digital display showing key
information like air pressure, oil temperature and maintenance
schedules. features an insulated outer casing to minimise noise
(67dB.A at 1m) and offers protection to inner components. Also fitted
with a drain valve tap at base of unit to ensure easy function tank
drain when required. model no. ssc12710D has a built in air dryer
allowing the unit to produce cleaner purified air especially required
when paint spraying. the dryer reduces the air temperature and
helps prevent corrosion which can cause air lines and fittings to
become clogged.
3. PREPARATION
MOdEL No:
SSC12710
SSC12710d
motor output (hp)
10
10
Voltage/Phase
415/3ph
415/3ph
rated supply (Amp)
32
32
max free Air Delivery
cfm (ltr/min)
30.2(860)
30.2(860)
max. Pressure psi/bar
145/10
145/10
tank capacity (ltr)
270
270
Weight kg
217
257
noise Level dB.A
67
67
noise Level LwA
n/A
n/A
overall size (WxDxH)
1550 x 590 x 1255
1550 x 590 x 1255
3.1. TRANSPORTING ANd HANdLING THE PACKEd
COMPRESSOR.
the packed compressor must be transported by qualified
personnel using a forklift truck. Before moving the compressor
ensure that the load-bearing capacity of the forklift truck is
sufficient to take the weight to be lifted. Position the forks
exclusively as shown in fig.1A. once the forks have been
positioned in the points indicated, lift slowly and smoothly.
never stand near the area where the compressor is being
handled and never stand on the crate while it is being moved.
fig.1A
fig.1b
7
dO NOT Put oBJEcts or PArts of tHE BoDY Into
tHE ProtEctIon GrILLs. never put your hands, fingers or
other parts of the body near moving parts of the compressor.
to do so may cause physical injuries and damage to the
compressor.
7
dO NOT toucH Hot PArts of tHE comPrEssor.
to avoid burns do not touch the compressor cylinder, cylinder
head, motor or pipe from head to tank as these may be hot and
will remain so for some time after shutdown.
3
ALWAYs WEAr sAfEtY GoGGLEs. Always wear goggles or
equivalent means of eye protection. never direct compressed
air towards any part of your body or that of others.
3
WEAr APProPrIAtE cLotHInG.
dO NOT wear unsuitable
clothing, ties or jewellery as these may get caught up in moving
parts. tie back long hair or wear a cap to cover your hair if
necessary.
3
ProtEct YoursELf AGAInst ELEctrIc sHocKs. Avoid
accidentally touching the metal parts of the compressor with
your body, such as pipes, the tank or metal parts connected to
earth. never use the compressor where there is water or in
damp rooms.
1.7. SAFETY (MAINTENANCE/PARTS).
WARNING! Compressor must only be serviced by an
authorised agent. dO NOT tamper with, or attempt to
adjust, pressure switch or safety valve.
3
sPArE PArts. use only original and identical spare parts to
replace worn or damaged ones. repairs must be made
exclusively by an authorised service agent.
3
mAIntEnAncE. regular maintenance of the compressor is
essential to ensure a long working life. follow the maintenance
schedule detailed in these instructions.
7
dO NOT dis-assemble compressor for any reason. the unit must
be checked by qualified personnel only.
3
dO drain condensation from tank daily, inspect inside
walls for corrosion every three months and have a
detailed tank inspection carried out annually. Tank shell
must not fall below the certified thickness at any point.
3
When not in use, store the compressor carefully in a safe, dry,
childproof location.
3
KEEP tHE IntAKE GrILLs cLEAn. Keep the motor
ventilation grills clean. regularly clean these grills if the work
area is particularly dirty.
7
dO NOT cLEAn PLAstIc PArts usInG soLVEnts.
solvents such as gasoline and thinners or other compounds
that contain hydrocarbons may damage the plastic parts. clean
them with a soft cloth and soapy water or other suitable liquids.
3
usE orIGInAL sPArE PArts onLY. the use of non-original
spare parts will invalidate the warranty and could seriously
damage the compressor. original spare parts are available
from your local sealey dealer.
3 moVInG or mAIntAInInG tHE comPrEssor. Disconnect
the compressor from the electric power supply and completely
discharge the pressure from the tank before moving it or
carrying out any service, inspection, maintenance, cleaning,
replacing or inspection of parts.
3
EnsurE tHAt EAcH scrEW, BoLt AnD GuArD Is
fIrmLY sEcurED In PLAcE.
WARNING! If an electrical fuse blows, ensure that it is
replaced with one of identical type and rating.
1.8. SAFETY (COMMON SENSE).
WARNINg: The warnings, cautions and instructions
discussed in this instruction manual cannot cover all
possible conditions and situations that may occur. It must
be understood that common sense and caution are factors
which cannot be built into this product, but must be
applied by the operator.
3
usE tHE comPrEssor EXcLusIVELY for tHE
APPLIcAtIons sPEcIfIED In tHIs InstructIon
mAnuAL. the compressor is a machine that produces
compressed air. never use the compressor for purposes other
than those specified in this instruction manual.
3
WArnInG. Pay attention to everything you do. use your
common sense.
dO NOT use the compressor if you are tired.
the compressor must never be used if you are under the
influence of alcohol, drugs or intoxicating medicines.
Original Language Version
ssc12710 & ssc12710D Issue: 3 - 23/02/12
dANGER! dO NOT DIrEct tHE JEt of comPrEssED AIr
DIrEctLY toWArDs Your BoDY. to avoid all risks never
direct the jet of air towards other people or animals.
7
dO NOT stoP tHE comPrEssor BY PuLLInG on tHE
PoWEr suPPLY cABLE (unless in an emergency). use the
on/off buttons on the control panel to stop the compressor.
7
dO NOT moDIfY tHE comPrEssor In AnY WAY.
contact your local sealey dealer for all repairs required. Any
unauthorised modification may impair the efficiency of the
compressor and may also cause serious accidents for those
who do not have the technical skill required to make such
modifications.
3
WE rEsErVE tHE rIGHt to mAKE moDIfIcAtIons
WHErE nEcEssArY WItHout notIcE.