TROUbLESHOOTING

NG

PRObLEM

POSSIbLE CAUSE ANd REMEdY

● Luminous

switch /

control panel

display off.

1. check if the line is electrically powered.

2. check cabling.

3. check the electronic control board; if the

trouble persists, replace it.

● The

compressor

will not start.

1. check cabling and control.

2. Activation of compressor’s internal thermal

protection; wait one hour and check again. If the

fault persists: stop dryer and call a refrigeration

engineer.

3. check the compressor’s electrical components.

4. short circuit in the compressor. replace it.

● The fan

doesn’t work.

1. check the protection fuse (if present), and

replace it if necessary.

2. check cabling.

3. check the electronic control board; if the trouble

persists, replace it.

4. short circuit in the fan. replace it.

● Condensate

drain absent

(no water or

air).

1. check cabling.

2. Drainage system pre-filter is dirty, clean it.

3. Drainage solenoid valve coil is burnt out,

replace it.

4. Drainage solenoid valve clogged/jammed, clean

or replace it. (fig.13)

5. check the electronic card, if the trouble

persists, replace it.

6. the temperature on the display of the control

panel is lower then the nominal value, call a

refrigeration engineer.

● Air flows

continuously

through the

condensate

drainage.

1. Drainage solenoid valve jammed, clean or

replace it. (fig.13)

2. Verify the condensate drainage times.

3. check the control. If the trouble persists,

replace it.

● Water in the

pipes

downstream of

the dryer.

1. the dryer is off; turn it on.

2. close by-pass (if present).

3. condensate drainage absent; see specific

section.

4. the temperature on the control panel display is

higher than the nominal value; see specific section.

● The

temperature

on the control

panel display

is higher than

the nominal

value.

1. check if the compressed air inlet/outlet is

connected properly.

2. the compressor doesn’t start; see specific

section.

3. the fan doesn’t turn; see specific section.

4. the flow rate and/or temperature of the air

entering the dryer are higher than the nominal

values; restore the nominal conditions.

5. the ambient temperature is higher than the

nominal values; restore the nominal conditions.

6. the condenser is dirty; clean it.

7. condensate drain absent (no water nor air);

see specific section.

8. check if the temperature control probe in the

evaporator is positioned improperly or faulty.

9. Gas leakage in the refrigerating circuit: stop

dryer and call a refrigeration engineer.

10. check cabling.

● The dryer

does not let

compressed

air flow

through.

1. check if the compressed air inlet/outlet is

connected properly.

2. the temperature on the control panel display is

lower than the nominal value; call a refrigeration

engineer.

3. check if the temperature control probe in the

evaporator is positioned improperly or faulty.

4. check if the connecting tubing is clogged.

5. check if by-pass (if present) is installed

properly.

6. check electronic control board. If the trouble

persists, replace it.

fig.13

Original Language Version

6.5. dRYER START UP.

6.5.1. the operations specified below must be performed after the

first start up and at each start up after a prolonged inactive

period of time due to maintenance operations, or any other

reason.

6.5.2. make sure that all instructions contained in chapters

InstALLAtIon sItE and InstALLAtIon have been

adhered to.

6.5.3. check if by-pass is locked properly (if fitted).

6.5.4. Activate current supply and press the on/off switch on the

control panel for at least 1 second.

6.5.5. Wait 5 to 10 minutes until machine has achieved its standard

operating parameters.

6.5.6. slowly open the air outlet valve and successively open the air

inlet valve.

6.5.7. If existent, close the by-pass.

6.5.8. check if the condensate drainer is working properly. check if

all connecting pipes are properly tightened and fixed.

before disconnecting the dryer from electrical power

supply, use ON/OFF key to stop the dryer. Wait 10 minutes

before switching the dryer on again, in order to allow freon

pressure re-balance.

6.6. dRYER MAINTENANCE.

before attempting any maintenance operation, make sure that:

a) No part of the system is under pressure.

b) No part of the system is electrically powered.

6.6.1.

WEEKLY OR EvERY 40 HOURS OF OPERATION

Verify the temperature on the control panel display.

Visually check if the condensate is drained.

6.6.2.

MONTHLY OR EvERY 200 HOURS OF OPERATION

clean the condenser with a compressed air jet, taking care not

to damage the cooling battery aluminium wings.

At the end of the above mentioned operations, check if the

dryer is working properly.

6.6.3.

YEARLY OR EvERY 2000 HOURS OF OPERATION

check if the flexible tube used for condensate drainage is

damaged and replace it if necessary.

check if all connecting pipes are properly tightened and fixed.

At the end of the above mentioned operations, check if the

dryer is working properly.

6.7. TROUbLESHOOTING.

notE: foLLoWInG conDItIons ArE normAL

cHArActErIstIcs of oPErAtIon AnD not fAuLts:

• Variable speed of the fan.

• Visualization of message ESA in case of operation without load.

• Visualization of negatives values in case of operation without load.

troubleshooting and eventual control and/or maintenance

operations must be performed by qualified personnel.

for maintaining the refrigerating circuit of the machine, contact

a refrigeration engineer.

IMPORTANT: The temperature control probe is extremely

delicate. dO NOT remove the probe from its position. In case of

any faults, please contact your Service Centre.

ssc12710 & ssc12710D Issue: 3 - 23/02/12