Sealey SAC3153B User Manual
Instructions for, Model nos, Fig.1
InstructIons for:
COMPRESSOR 150/200ltr BELT dRivE
3.0hp WiTH FRONT CONTROL PANEL
model nos:
SAC3153B/SAC3203B
thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
1. SAFETY iNSTRUCTiONS
IMPORTANT: PLEASE REAd THESE iNSTRUCTiONS CAREFULLY. NOTE THE SAFE OPERATiONAL REQUiREMENTS, WARNiNGS & CAUTiONS. USE
THE PROdUCT CORRECTLY ANd WiTH CARE FOR THE PURPOSE FOR WHiCH iT iS iNTENdEd. FAiLURE TO dO SO MAY CAUSE dAMAGE OR
PERSONAL iNJURY ANd WiLL iNvALidATE THE WARRANTY. PLEASE KEEP iNSTRUCTiONS SAFE FOR FUTURE USE.
from
pump
to receiver
decompression
tube from switch
fig.1
non return valve
Hose reel tidy
safety valve
Original Language Version
sAc3153B/sAc3203B Issue no: 1 - 01/06/13
© Jack sealey limited 2013
1.1
ELECTRiCAL SAFETY.
WARNiNG! it is the user’s responsibility to read, understand and
comply with the following:
You must check all electrical equipment and appliances to ensure they
are safe before using. You must inspect power supply leads, plugs and all
electrical connections for wear and damage. You must ensure the risk of
electric shock is minimised by the installation of appropriate safety
devices. An rccB (residual current circuit Breaker) should be
incorporated in the main distribution board. We also recommend that an
rcd (residual current device) is used with all electrical products. It is
particularly important to use an rcd together with portable products that
are plugged into an electrical supply not protected by an rccB. If in
doubt consult a professional electrician. You may obtain a residual
current device by contacting your sealey dealer. You must also read
and understand the following instructions concerning electrical safety.
1.1.1 the electricity At Work Act 1989 requires all portable electrical
appliances, if used on business premises, to be tested by a
qualified electrician at least once a year, using a Portable
Appliance tester (PAt).
1.1.2 the
Health & Safety at Work Act 1974 makes owners of
electrical appliances responsible for the safe condition of the
appliance, and the safety of the appliance operator. If in any
doubt about electrical safety, contact a qualified Electrician.
1.1.3 ensure the insulation on all cables and the product itself is safe
before connecting to the mains power supply. see 1.1.1. & 1.1.2.
above and use a Portable Appliance tester (PAt).
1.1.4 ensure that cables are always protected against short circuit and
overload.
1.1.5 regularly inspect power supply, leads, plugs and all electrical
connections for wear and damage, especially power connections,
to ensure that none are loose.
1.1.6 Important: ensure the voltage marked on the product is the same as the
electrical power supply to be used, and check that plugs are fitted with
correct capacity fuse.
1.1.7
dO NOT pull or carry the powered appliance by its power supply
lead or output cables.
1.1.8
dO NOT pull power plugs from sockets by the power cable.
1.1.9
dO NOT use worn or damage leads, plugs or connections.
Immediately replace or have repaired by a qualified electrician.ug.
1.1.10. Model Nos SAC3153B and SAC3203B are supplied with a
flying lead without a plug. Jack Sealey Limited recommend a
16 amp protected supply. When connecting to a 16 amp
protected supply, contact a qualified electrician to ensure
connect to a suitably rated supply.
*Provided a good 230V supply is available and the lead
length is not increased from that supplied, the compressor
may operate from a 13 amp supply. This very much depends
upon the quality of your power supply.
1.2.
Wiring a BS 1363/A UK 3 Pin Plug.
WARNiNG! if in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth
terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that
all wires have been correctly connected, that the cable
outer insulation extends beyond the cable restraint and
that the restraint is tight.
double insulated products, which are always marked with
this symbol , are fitted with live (brown) and neutral (blue)
wires only. to rewire, connect the wires as indicated in
diagram.
dO NOT connect either wire to the earth terminal.
We recommend that you discuss the installation of an
industrial round pin plug and socket with your electrician.
iMPORTANT! the use of extension leads to connect these
compressors to the mains is not recommended as the
resulting voltage drop reduces motor, and therefore pump
performance.
RECOMMENdEd
FUSE RATiNG:
*13 AMP
see 1.1.10 for power supply options.