Sealey SAC82425VLN User Manual
Instructions for, Model no's, Safety instructions
instructions for:
Low Noise compressors
2.5hp, 230v
moDEL no's:
sAc89025vLN, sAc82425vLN
thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
1. sAFeTY iNsTrUcTioNs
IMPORTANT: pLeAse reAD THese iNsTrUcTioNs cAreFULLY. NoTe THe sAFe operATioNAL reQUiremeNTs, wArNiNGs AND cAUTioNs.
Use THe proDUcT correcTLY AND wiTH cAre For THe pUrpose For wHicH iT is iNTeNDeD. FAiLUre To Do so mAY cAUse
DAmAGe AND/or persoNAL iNJUrY AND wiLL iNvALiDATe THe wArrANTY. pLeAse Keep iNsTrUcTioNs sAFe For FUTUre Use.
1.1
eLecTricAL sAFeTY.
wArNiNG! It is the user’s responsibility to read, understand and
comply with the following:
You must check all electrical equipment and appliances to ensure they
are safe before using. You must inspect power supply leads, plugs and
all electrical connections for wear or damage. You must ensure the risk
of electric shock is minimised by the installation of appropriate safety
devices. An rccB (residual current circuit Breaker) should be
incorporated in the main distribution board. We also recommend that a
rcD (residual current Device) is used with all electrical products. it is
particularly important to use an rcD with portable products that are
plugged into an electrical supply not protected by an rccB. if in doubt
consult a qualified electrician. You may obtain a residual current Device
by contacting your sealey dealer. You must also read and understand
the following instructions concerning electrical safety.
1.1.1 the Electricity At Work Act 1989 requires all portable electrical
appliances, if used on business premises, to be tested by a qualified
electrician, using a Portable Appliance tester (PAt), at least once a year.
1.1.2 the Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3 Ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply. see 1.1.1. & 1.1.2.
above and use a Portable Appliance tester (PAt).
1.1.4 Ensure that cables are always protected against short circuit and overload.
1.1.5 regularly inspect power supply leads and plugs for wear or damage and connections to ensure that none are loose.
1.1.6 Important: Ensure the voltage marked on the product is the same as the electrical power supply to be used, and check that plugs are
fitted with the correct capacity fuse.
1.1.7
Do NoT pull or carry the powered appliance by its power supply lead.
1.1.8
Do NoT pull power plugs from sockets by the power cable.
1.1.9
Do NoT use worn or damage leads, plugs or connections. immediately replace or have repaired by a
qualified electrician.
1.1.10 A u.K. 3 pin plug with AstA/Bs approval is fitted. in case of damage, cut off and fit a new plug
according to the following instructions (uK only - see diagram at right). Discard old plug safely.
Ensure the unit is correctly earthed via a three-pin plug.
a) connect the green/yellow earth wire to the earth terminal ‘e’.
b) connect the brown live wire to the live terminal ‘L’.
c) connect the blue neutral wire to the neutral terminal ‘N’.
d) ensure the plug is fitted with a 13Amp fuse.
e) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer
insulation extends past the cable restraint and that the cable restraint is tight.
1.2 GeNerAL sAFeTY iNsTrUcTioNs
3
familiarise yourself with the application and limitations of the compressor.
3
Ensure that the compressor is in good order and condition before use. if in any doubt
Do NoT use the unit and contact an electrician/
service agent.
imporTANT! the compressor must be installed and commissioned by qualified personnel.
wArNiNG! compressor must only be serviced by an authorised agent. Do NoT tamper with, or attempt to adjust, pressure
switch or safety valve.
3
Before moving or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been
vented.
3
maintain the compressor in good condition and replace any damaged or worn parts. use genuine parts only. Unauthorised parts may
be dangerous and will invalidate your warranty.
3
read the instructions regarding any accessory used with the compressor. Ensure the safe working pressure of any air appliance used
exceeds the compressor regulator. if using a spray gun, check the area selected for spraying is provided with an air change system or
ventilation.
3
Ensure the air supply valve is turned off before disconnecting the air supply hose.
3
use the compressor in a well ventilated area and ensure it is placed on a firm surface away from any heat sources.
3
Keep tools and other items away from the compressor when it is in use and keep area clean and clear of unnecessary items.
3
Ensure the air hose is not tangled, twisted or pinched.
3
Keep children and unauthorised persons away from the working area.
7
Do NoT dis-assemble compressor for any reason. the unit must be checked by qualified personnel only.
7
Do NoT use the compressor outdoors, or in damp, or wet, locations and Do NoT operate within the vicinity of flammable liquids,
gases or solids.
7
Do NoT touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot and will remain so for some time
after shutdown.
Original Language Version
sAc89025VLn, sAc82425VLn issue: 2 - 22/02/12
FUse rATiNG: 13Amp