apply Section 1 safety instructions.

7.1. MAINTENANCE SCHEdULE TAbLE.

7.1.1.

before performing any jobs within the sound-proof

cabinet, ensure that: The main line switch is turned off

(position “0”) The compressor is disconnected from the

compressed air system and all the pressure has been

released from the compressor and internal pneumatic

circuit.

7.1.2.

Weekly: it is advisable to inspect the compressor, paying

special attention to oil leaks and scale due to settled dust and

oil.

7.1.3.

Note! If the compressor is used for more than 3000 hours/

year the tasks indicated below are to be performed more

frequently.

7. COMPRESSOR MAINTENANCE

Interval

(hours)

TASKS TO bE PERFORMEd

See

section

Weekly

check if the filters of the electric cabinet are clogged
check if the anti-dust pre-filter is clogged

7.8

Drain condensate on a weekly basis.

500

hours

after

first

start

change oil and oil filter.

7.2

& 7.3

check the electrical connections and tighten if necessary

every

2500

hours or

at least

every

year

replace the oil filter cartridge

7.3

replace the oil separator filter cartridge

7.4

replace the air filter cartridge

7..5

check the transmission

7.6

clean the air/oil radiator.

7.9

check filters in electrical cabinet and replace if

necessary
clean inverter dissipator (if equipped)
check the safety valve
check the electrical connections and tighten if necessary
change oil

7.2

every

7500

hours

check the hydraulic seals
overhaul the suction valve

every

12500

hours

check the hoses and replace if necessary
overhaul oil separator flange
Grease the minimum pressure valve
replace fluorflon pipes 6x4 and 10x10
replace the screw oil seal
replace the screw oil seal
replace the bearings of the radiator fan motor (to be

done by service centre).
replace the delivery or flange
clean the compressor externally when not in use

every

20000

hours

replace inverter fan (if equipped)
replace the bearings of the screw (to be done by

technical service centre)

7.2 CHANGING THE OIL.

7.2.1 change the oil following the initial

500 hours of use and then

every

2500 hours thereafter, or at least once a year.

In case of infrequent use (only a few hours of duty per

day) you should change the oil every 6 months.

7.2.2 referring to fig.14 identify the oil filler cap (1) and the oil drain

tap (2). unscrew the oil filler cap (1) and put to one side.

Ensure that the oil drain tap is shut off (i.e. tap handle at 90° to

the body of the tap). Have to hand a pipe and container ready

to collect the oil.

7.2.3. unscrew the hex nut from the end of the oil drain tap. screw in

the tail piece attachment supplied with the compressor. Push

the pipe onto the tailpiece and ensure that the other end is in

the collection container. open the drain tap fig.14-2. once

emptied, close tap, remove the tail piece attachment and

screw the hex nut (with seal) back into place.

7.2.4. fill-up with oil as shown in fig.15 until the level is halfway up

the sight glass. see fig.15-3. screw oil filler cap (1), with its

seal, back into the oil filler hole.

7.2.5. once the oil and oil filter have been changed follow the initial

start up procedure by pressing the stArt & stoP buttons on

and off for 3 or 4 seconds to start the machine intermittently.

After this, leave the compressor to run for roughly 5 minutes

then turn it off and check the oil level again.

Check the oil

level once a month.

7.2.6. never mix different types of oil, therefore always ensure that

the circuit is completely empty before filling-up with oil. Each

time the oil is changed the filter is also to be replaced.

fig.15

Original Language Version

fig.14

7.2.7.

Recommended oil.

mineral oil : Grade 46st

Part No.

Qty.

description

scPo1s 1ltr

mineral oil.

scPo5

5ltr

mineral oil.