Problem

Possible cause

solution

Heater fires, but main PCB shuts

heater off after a short period of time.

Lamp is flickering.

1. Incorrect pump pressure

1. Adjust pump pressure

2. Dirty input, output or lint filter

2. clean/replace Air filter

3. Dirty fuel filter

3. clean/replace fuel filter

4. nozzle is dirty

4. clean/replace nozzle

5. Photocell lens is dirty

5. clean/replace Photocell

6. Photocell not installed properly

6. Adjust Photocell position

7. Photocell Defective

7. replace Photocell

8. Improper electrical connection between Main

PcB and Photocell

8. check wiring connections (see Wiring

Diagram)

9. Ambient temperature too low for fuel type

9. change fuel type

Heater will not operate or motor runs for a

short time. Lamp flickers.

1. No paraffin in fuel tank

1. Fill tank with fresh paraffin

2. Incorrect pump pressure

2. Adjust pump pressure

3. corroded spark Plug or incorrect gap

3. clean/adjust/replace spark plug

4. Dirty fuel filter

4. clean/replace fuel filter

5. Dirty nozzle

5. clean/replace nozzle

6. Moisture in fuel/fuel tank

6. Rinse out fuel tank with fresh paraffin

7. faulty electrical connection

7. Inspect all electrical connections

8. Ignitor Wire not connected to spark Plug

8. re-attach Ignitor Wire to spark Plug

9. Defective Ignitor

9. replace Ignitor

fan does not operate when heater is

plugged in and Power switch is in the

“ON” position. The lamp is flickering or on.

1. thermostat is set too low

1. rotate thermostat to a higher setting

2. Broken electrical connection between Main

PcB and motor

2. Inspect all electrical connections

Lamp flickering.

1. thermostat switch has failed

1. replace thermostat switch

Poor combustion.

1. flames extending beyond heater

1. Decrease Pump Pressure

2. Low heat output

2. Increase Pump Pressure

Heater does not turn on and the lamp is

not lit.

1. temperature limit sensor has overheated

1. Push Power switch to “off” and allow heater

to cool for 10 minutes. Push Power switch

back “on”

2. no electrical power

2. check power cable and extension cable

connections. test power supply.

3. fuse Blown

3. check/replace fuse

4. faulty connection between temperature Limit

sensor and PcB

4. Inspect all electrical connections

8. TRoUBLESHooTING

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email

[email protected] or phone 01284 757500.

NOTe: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPoRTANT: no liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFoRMATIoN: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole Uk distributor, Sealey Group,

Kempson Way, suffolk Business Park

,

Bury st. Edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

WARNING! this heater is not suitable for use with Bio-Diesel; use of Bio-Diesel will damage the filter

and seals. Damage caused by use of Bio-Diesel will not be covered by warranty.

Original Language Version

AB458.V2, AB708.V2,

AB7081.V2, AB7081ss Issue no: 4 - 19/04/12

This manual is related to the following products: