7. MAINTENANCE

WARNING! MAINTeNANce MusT ONly Be

UnDertaken By a qUalifieD person. We

sTRONGly RecOMMeND THAT All seRVIcING Is

Done By yoUr local service aGent.

7.0

MAINTENANCE SCHEdULE

WARNING! Never attempt to service the heater whilst it is

still hot, wait until it has cooled enough to touch. Unplug

the heater from the mains supply before servicing.

use only genuine sealey replacement parts. use of

alternative/third party components will cause unsafe operation

and will invalidate your warranty.

7.1

FUEL TANk

clean out the fuel tank every 200 hours of operation or as

needed. flush out with paraffin, kerosene or diesel fuel

depending on which fuel you are using. Do not use any other

liquid for this operation.

7.2

AIR FILTERS (See fig.6)

the air intake filter should be replaced or washed with soap

and water and thoroughly dried every 500 hours of operation.

or less, depending on the conditions of operation.

the air output filter and lint filter should be replaced every

500 hours or more frequently depending on conditions of use.

7.3

FAN BLAdES (See fig.7)

the fan blades should be cleaned at least once per heating

season, depending on conditions in the area of use. remove

all accumulated dust and dirt with a damp cloth, taking care

not to bend any of the fan blades. Dry the fan blades

thoroughly before restarting the heater. for fan removal see

fig.7.

7.4

NoZZLE (See fig.8)

the nozzle should be cleaned at least once per heating

season. use of contaminated fuel will make it necessary to

clean the nozzle more frequently. to clean dirt from the

nozzle, blow compressed air through the front of the nozzle. It

may be necessary to soak the nozzle in paraffin, kerosene

first in order to loosen any dirt particles.

7.5

SPARk PLUG (See fig.9)

clean and re-gap the spark plug every 600 hours of

operation, or replace if needed. After removing the spark

plug, clean the terminals with a wire brush. re-gap the

terminals to 3.5mm (0.140").

7.6

PHoTo CELL (See figs.10&11)

the photocell should be cleaned at least once per heating

season or more depending on conditions of use. use a cotton

swab dipped in water or alcohol to clean the lens of the

photocell. the positioning of the photocell is critical to its

correct operation. see fig.11 for the correct installation.

fig.6

fig.7

fig.8

fig.9

fig.10

fig.11