7.7

FUEL FILTER (See fig.12)

the fuel filter should be cleaned at least twice per heating

season by rinsing it in clean paraffin or kerosene. use of

contaminated fuel will make it necessary to clean the filter

more frequently. to remove the filter first squeeze the legs of

the fuel line clip and move it up the fuel line. Ease the fuel

line from off the filter head. turn the hexagonal head of the

filter 90° anti-clockwise and ease it upwards and out of the

tank.

7.10 LoNG TERM SToRAGE

If the heater is to be stored for a long period of time, drain the

fuel through the fuel cap opening. rinse and swirl a small

amount of fuel within the tank and then empty it fully. When

you come to use the heater again do not use old fuel which

has been stored from the previous season. use of old fuel can

damage your heater.

7.8

PUMP PRESSURE AdJUSTMENT (See fig.13)

for the efficient burning of fuel and optimum heat output the

pumps on these heaters are designed to run at the specific

pressures indicated below.

ModEL No:

PUMP PRESSURE

AB458

3.0PsI ±10%

AB708

3.7PsI ±10%

AB7081 / AB7081ss 3.7PsI ±10%

Periodically check the pump pressure by referring to the

pressure gauge within the rear grille. If adjustment is required

turn the adjusting screw located to the right of the gauge

using a slotted screwdriver as shown in fig.13.

fig.12

fig.13

WARNING! Do not substitute the fuse with one of a higher or

lower current rating as this may result in a fire hazard.

7.9.5 reconnect switch wires to the power switch for thermostatic

models AB708, AB7081 & AB7081ss.

7.9.6 replace side panel.

7.9

FUSE REPLACEMENT (See fig.14)

NoTE: This is a fuse protected heater.

If your heater fails to ignite check the fuse as shown in fig.14

before contacting your local service agent.

WARNING! unplug the heater from the mains power supply

before attempting any maintenance work.

7.9.1 remove the control panel screws using a medium phillips

screwdriver and lift off the side panel to reveal the printed

circuit board.

7.9.2 Disconnect switch wires from the power switch for

thermostatic models AB708, AB7081 & AB7081ss.

7.9.3 remove fuse from holder as shown below.

7.9.4 replace fuse with one of the same specification.

fig.14

Although our heaters operate with diesel fuel, when the temperature

is below 0°c diesel additives are required to maintain the diesel's

viscosity. typically diesel can cloud in freezing conditions and will

start to gel. You will need additives for your fuel in these conditions.

Kerosene/Paraffin does not start to gel until the ambient

temperature is around -40°c.