Sealey IWMH2003 User Manual
Infrared quartz heater, Instructions for, Model no
1.1
ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and
any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of
appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also
recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are
plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual
Current Device by contacting your Sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
1.1.1 The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2 The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3 Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1 and 1.1.2 and
use a Portable Appliance Tester.
1.1.4 Ensure that cables are always protected against short circuit and overload.
1.1.5 Regularly inspect power supply cables and plugs for wear or damage and check all connections to
ensure that none are loose.
1.1.6
Important: Ensure that the voltage marked on the appliance matches the power supply to be used and
that the plug is fitted with the correct fuse - see fuse rating at right.
1.1.7
DO NOT pull or carry the appliance by the power cable.
1.1.8
DO NOT pull the plug from the socket by the cable.
1.1.9
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item
repaired or replaced by a qualified electrician. When a BS 1363/A UK 3 pin plug is damaged, cut the
cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly
connected, that the cable outer insulation extends beyond the cable restraint and that the
restraint is tight. Double insulated products, which are always marked with this symbol , are fitted with live (brown) and neutral
(blue) wires only. To rewire, connect the wires as indicated above -
DO NOT connect either wire to the earth terminal.
1.1.10 Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure
that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with
your electrician.
1.1.11 Use of an extension cord is not recommended. If an extension reel must be used it should be fully unwound before connection. A reel with
an RCD fitted is preferred since any appliance plugged into it will be protected.
The cable core section is important and should be at least 2.5mm².
1.2
GENERAL SAFETY INSTRUCTIONS
Familiarise yourself with the applications and limitations of the heater.
Ensure the heater is in good order and condition before use. If in any doubt do not
use the unit and contact an electrician.
Only use recommended attachments and parts. To use unauthorised parts may be
dangerous and will invalidate your warranty.
Check that element guards are in place, undamaged and firmly attached.
Keep tools and other items away from the heater when it is in use.
Keep the work area clean and clear of unnecessary items.
Keep children and unauthorised persons away from the heater, as it gets
very hot.
Disconnect from mains and allow to cool before moving or attempting any cleaning
or maintenance.
DO NOT get the heater wet or use in damp or wet locations or areas where there is condensation.
DO NOT locate the heater below the power outlet.
DO NOT move the heater whilst in operation or even when still warm.
DO NOT touch the heater elements, even when cold.
DO NOT disassemble the heater for any reason. The heater must be checked by qualified personnel only.
DO NOT use this product to perform a task for which it has not been designed.
WARNING! If a fuse blows, ensure it is replaced with an identical fuse type and rating.
When not in use, store the heater carefully in a safe, dry, childproof location.
WARNING! Never touch the element glass directly with fingers. Use a soft cloth, otherwise the tube may get damaged.
WARNING! Ensure the heater is at least 900mm from any object.
IMPORTANT! This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities
or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance
1. SAFETY INSTRUCTIONS
INSTRUCTIONS FOR:
INFRARED qUARTz hEATER
mODEl No
:
IWMh2003.V2
Thank you for purchasing a Sealey product. manufactured to a high standard this product will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ ThESE INSTRUCTIONS CAREFULLY. NOTE ThE SAFE OPERATIONAL REqUIREMENTS, WARNINGS, AND CAUTIONS.
USE ThIS PRODUCT CORRECTLY, AND WITh CARE FOR ThE PURPOSE FOR WhICh IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE
AND/OR PERSONAL INJURY AND WILL INVALIDATE ThE WARRANTY.
Original Language Version
IWmH2003.V2 Issue: 1 - 31/05/12
FUSE RATING 13AMP