Setting the scald protection
The cartridge
7
in this tap has a scald protection function. This function
is not activated before leaving the factory (neutral setting) (see fig. C / I).
Note: Do not alter the setting of the scald protection until you have
installed the tap.
Note: This step requires an Allen wrench (2.5 mm) and an open-end
spanner SW 30 mm or fitting pliers.
Follow these steps:
Switch off the general water supply.
Remove the hot / cold plaque
3
by moving the handle
1
into
top-most position and pushing the plaque
3
out carefully from
inside with a long, flat object.
Loosen the locking screw
2
with an Allen key (2.5 mm) by turn-
ing counter-clockwise.
CAUTION! Do not unscrew the screw completely. Only loosen
this as far as is necessary to remove the handle
1
.
Remove the handle
1
.
Unscrew the cartridge covering ring
4
.
Loosen the cartridge locknut
5
; this requires an open-end span-
ner SW 30 mm or fitting pliers.
Now pull the red hot-water limiting ring
6
upwards using a
screwdriver.
Note: Press the cartridge pins slightly backwards. This will make
it easier to pull up on the hot water limiting ring
6
.
Reducing the hot water flow rate:
Reinsert the hot water limiting ring
6
offset as shown in Fig. C / II.
Reducing the hot water flow rate completely:
Attach the hot water limiting ring
6
as shown in Fig. C / III.