Tighten the lower eccentric section
21 a
with the lower seal
22
hand tight below the washbasin and verify the eccentric rod
19
is
facing to the back.
Attach the clamping plate and the eccentric joint
20
to the eccen-
tric rod
19
.
Attach the pull rod
18
and the eccentric rod
19
to the eccentric
joint
20
.
Verify the eccentric
21
is functioning properly. The screw below
the drain plug may possibly need to be adjusted. Then secure with
the counter nut again.
Verify the seals
16
are inserted in the swivel nuts on the connect-
ing hoses
15
.
Screw the connecting hoses
15
onto your angle valves. Be sure to
correctly attach the two connecting hoses
15
to the cold and hot
water connections.
Start-up
After the initial commissioning, carefully check all connections for leaks.
To remove any possible impurities the tap must be flushed before being
used for the first time. To do this, proceed as follows:
Unscrew the aerator
9
from the fitting body
8
.
Open the main water supply and allow the water to flow for two
minutes to flush out any residues.
Then reattach the aerator
9
to the fitting body
8
.