Installation / operation, Operation start-up – Miomare LED Washbasin Fitting / LED Bath/Shower Fitting User Manual
Page 32

32 GB
Installation / Operation
designated female threads on the fitting
1
(see Fig. C2).
Unscrew the handle from part 1 of the pop-up
pull rod
3
and insert it into the fitting
1
from
the bottom up so the female thread on the han-
dle faces to the back through the rear opening
on the fitting. Then screw it to the handle (see
Fig. C3).
Position the fitting
1
over the washbasin tap
hole (see Fig. C4).
Below the washbasin first place the C sealing
washer
6
, then the C metal washer
7
over
the two thread bolts
8
(see Fig. C4).
Now screw the securing nuts
9
onto the thread
bolts
8
and tighten with a spanner SW 9 mm
until the fitting
1
is firmly seated on the
washbasin (see Fig. C4).
Unscrew the upper pop-up flange
15
from the
lower pop-up flange
17
.
From the top insert the upper pop-up flange
15
with the upper pop-up seal
14
into the wash-
basin drain hole.
Place the lower pop-up flange
17
with the lower
pop-up seal
16
beneath the washbasin drain
hole.
Now screw together the lower pop-up flange
17
and the upper pop-up flange
15
so the
pop-up plastic nut
19
faces to the back (see
Fig. C5).
Unscrew the pop-up plastic nut
19
from the
lower pop-up flange
17
, leaving the seal in-
side the female thread of the lower pop-up
flange
17
.
ATTENTION! DANGER OF INJURY, SHEET
METAL HAS SHARP EDGES.
Temporarily remove the clip and pop-up joint
11
from the pop-up pivot rod
12
for installation.
Be sure the seal remains on the pop-up pivot
rod
12
.
Place the pop-up plastic nut
19
over the longer
piece of the pop-up pivot rod
12
. Be sure the
seal is placed between the ball and pop-up
plastic nut
19
.
Inset the short section of the pop-up pivot rod
12
into the female thread of the lower pop-up
flange
17
and retighten the pop-up plastic nut
19
hand tight.
Reattach the clip and pop-up joint
11
to the
pop-up pivot rod
12
.
Insert the pup-up pull rod
5
through the plas-
tic section of the pop-up joint
11
and tighten
the screw using a cross-tip screwdriver.
Verify the pop-up is working properly. The plas-
tic screw below the pop-up drain plug
13
may
need to be adjusted. Then retighten with the
lock nut.
Install the siphon by screwing together the
siphon and the pop-up screw thread
18
.
Check the seals inside the swivel nuts
20
on
the flexible connection hoses
10
.
Screw the flexible connection hoses
10
to the
angle valves. Be sure to correctly install the
flexible connection hoses
10
to the cold- / hot
water hoses – left flexible connection hose
10
to the hot water connection, left angle valve,
and the right flexible connection hose
10
to
the cold water connection, right angle valve
(refer to Fig.C5).
Operation
Start-up
After the initial commissioning, carefully check all
connections for leaks.
Check the operation of the fitting. To do so,
swing the handle
23
into all permissible posi-
tions.
Note: the fitting
1
features an LED light. The LED
is lit through an integrated turbine (without batteries).
The LED colour changes automatically based on the
water temperature through an integrated tempera-
ture sensor:
· up to approx. 33°C blue,
· from approx. 33-43°C green,
· over approx. 43°C red.
Note: over approx. 53°C the LED light will begin
to flash red to warn of potential scalding.