View cup ring cycles related to surevend, View number of cup ring cycle failures, View home switch use related to surevend – Everpure 327 User Manual
Page 68

Cold Drink Center (327/328) Operator’s Guide
August, 2003
Page 62
3280020
VIEW CUP RING CYCLES RELATED TO SUREVEND™
(Not Shown If Zero)
1.
Press
, then press
until the display shows
SV.TOT XX
.
XX represents the number of vends during which more than one ring cycle
was required to successfully dispense a cup.
2.
Press
to clear the count.
3.
CONTINUE.
VIEW NUMBER OF CUP RING CYCLE FAILURES
(Not Shown If Zero)
1.
Press
, then press
until the display shows
SV.FL1 XX
.
XX represents the number of times a cup was not detected after ring 1
cycled. Check the cup ring adjustment (see "Cup mechanism
adjustment." on page 12), or the cup stack for damage if the count is
excessive.
2.
Press
to clear the count.
3.
Press
until the display shows
SV.FL2 XX
. XX represents the number
of times a cup was not detected after ring 2 cycled. Check the cup ring
adjustment (see "Cup mechanism adjustment." on page 12), or the cup
stack for damage if the count is excessive.
4.
CONTINUE.
VIEW HOME SWITCH USE RELATED TO SUREVEND
(Not Shown If Zero)
1.
Press
, then press
until the display shows
WO.SV XX
.
XX represents the number of times home switches were used due to
OPT
’
N SURE.V
selected but not working.
2.
CONTINUE.