Test the carbonator, Coolsan operation, Test the carbonator coolsan operation – Everpure 327 User Manual
Page 72

Cold Drink Center (327/328) Operator’s Guide
August, 2003
Page 66
3280020
TEST THE CARBONATOR
This screen serves several functions. One is to test the refill capability of the car-
bonator pump. The second is to empty the carbonator before storage or shipping.
The third function is to dispense still water.
1.
Press
, then press
until the display shows
CARB TEST
.
2.
Press
to test the carbonator. The carbonator will dispense until it is
empty, then it will refill. As it fills, the display will show the refill time. You
can adjust the carbonator pump to set the refill time to 15 - 25 seconds.
3.
Press
to run non-carbonated water through the dispensing lines.
4.
Press
to empty the carbonator without refilling. Before doing this,
you should turn off water to the machine and dispense still water (see step 2)
until the feeder cup is empty.
5.
CONTINUE.
COOLSAN OPERATION
1.
Remove the ice chute from the machine.
2.
Empty the waste pail and place it directly under the ice maker door using the
hook provided.
3.
Press
, then press
until the display shows
COOL SAN
.
4.
Press and hold the
key. The display will briefly show "
CLEARING
" and
three beeps will sound. Release the
key.
5.
Coolsan will empty the ice maker (approximately 3-5 minutes). The display
will flash the "
DUMP ICE
" message transposed with the time left for the
coolsan process to complete. All messages will flash between the current
operation notification and the time left in the coolsan process. The operator
may remove the pail when all the ice is visually removed from the hopper.