Everpure 327 User Manual
Page 77

Cold Drink Center (327/328) Operator’s Guide
3280020
Page 71
August, 2003
KEYSWITCH
The keyswitch input is active and configured as an inhibit.
D+J+WXYZ
Configuration error; displays the machine configuration screen.
NOTE: this is the actual config screen. You may enter the cor-
rect config number directly on this screen without further
action.
RING 1, 2
The cup ring is jammed.
MTR 1A1B2X
Cup turrets are jammed
NO CUPS 1, 2
Out of cups.
WASTE PAIL
The waste pail is full.
DOOR JAM
The automatic delivery door is jammed.
NO MECH
Coin mech not detected - machine will not operate if config-
ured for coin mech.
MECH COMM
Incomplete coin mech communications — check harness.
MECH.SENSOR
Coin mech reporting a bad tube sensor — replace mech.
MECH ROM
Replace the coin mechanism.
MECH.ACCEPT
Coin mechanism acceptor section is unplugged from the main
body of the coin mech. Connect the cable and cycle machine
power OFF and then ON.
MECH JAM
One or more coin tubes are jammed. Pay a coin from each
tube until the jam is cleared.
DEBIT CARD
Card reader reporting error — machine will not operate if con-
figured for DEBIT ONLY.
CHECK DBV
Bill validator reporting error — machine will not operate.
Empty stacker, clear jams, etc.
DBV COMM
Incomplete bill validator communications — check harness.
DBV MOTOR
One of the motors has failed. The unit will disable itself until
the error is corrected. Check for bill stuck in the acceptance
path. If no bill is present, replace the validator. Cycle machine
power OFF and then ON.
DBV SENSOR
One of the sensors in the bill validator has failed. The unit will
disable itself until the error is corrected. Check for bill stuck in
the acceptance path. If no bill is present, replace the validator.
Cycle machine power OFF and then ON.
DBV JAM
A bill is jammed in the acceptance path. The unit will disable
itself until the error is corrected. Remove bill stuck in the
acceptance path. Cycle machine power OFF and then ON.
DBV STACKR
The stacker is open or removed. The unit will disable itself
until the error is corrected. Install the stacker correctly.
CHK PRICE
Price error detected and changed to maximum - check prices.
LOCKS SET
All selection keys are locked out.
NONE READY
All selections are reported out of service.
SV.ERR CUP 1
Cup ring 1 is out of service due to a SureVend™ error.
SV.ERR CUP 2
Cup ring 2 is out of service due to a SureVend™ error.