Crivit 1-LD3814 User Manual
Page 14

- 51 -
Chest belt
Operating temperature
0-50°C
Dimensions
7 x 3,3 x 1,2 cm
Frequency
110 kHz
Weight
51g
Battery
CR 2032/3V
Features
Heart rate measurement
•
Alarm for maximum heart rate
•
Target heart rate training with timer and alarm
(Health, Fitness, Peformance and user defined)
•
Max. heart rate, min. heart rate and average heart rate
•
Warning light for high heart rate
Calorie features
•
Calories and fat burned during training
•
BMI-calculation
•
Fitness Level
Stop watch
•
1/100 seconds with 99 lap times
Countdown timer
Time features
•
Time
•
Calendar
•
Alarm with snooze
•
Hourly chime
•
Second time zone
- 52 -
Other
•
Back light
Important safety information
ATTENTION:
Consult your doctor before you begin any
training program. Your doctor can help you choose the
proper training intensity and heart rate guidelines for your
exercises.
This heart rate wrist watch is not a medical device and should
only be used as a guide for your training.
- Batteries
Insert the batteries/ rechargeable batteries in the correct polarity. Don’t try to
recharge non-rechargeable batteries and under no circumstances throw them into
fire. Danger of explosion.
Do not use unequal batteries (old and new, Alkaline and carbon, etc.)
simultaneously. If you will not use the device for a long time, remove the batteries
and store the device in a dry and dust-free place. Improper use of batteries may
cause an explosion or leakage. If the batteries have leaked, use gloves and clean
the appliance thoroughly with a dry cloth.
- Electrical devices should not be in the hands of children
Never let children use electrical devices unsupervised. Children can’t always
recognize the possible dangers properly. Batteries/ rechargeable batteries can
be life threatening when swallowed. Store the batteries where they cannot be
reached by small children. If a battery is swallowed, medical aid must be sought
immediately.
Also keep the packaging foils away from children. Danger of suffocation.
- 53 -
Setup of the heart rate monitor
Use a coin to unscrew the battery cover on the back side of the chest belt and
insert the 3V battery with the (+) sign facing up. Screw the battery compartment
cover back into the case.
Remove the protective film from the display and press MODE, SEL or SET.
Now select English, German, French or Spanish language by pressing SEL and
confirm your setting by pressing SET.
Select the unit KM-KG
METRIC
KM - KG
KM - KG
KM - KG
or Miles/pounds
IMPERIAL
M - LB
M - LB
M - LB
in the same way. Complete the setting procedure by pressing MODE.
battery CR2032
- 54 -
Reset
The watch can be reset by pressing and holding SET and SEL together. Only after
reseting the watch the other language can be selected.
Replacing the watch battery
The battery replacement can be performed by a watch maker in addition to a
water resistance test.
To replace the battery yourself, please read the following instructions first:
Remove the screws (1, 2, 3 and 4) from the back side of the watch with a small
Phillips screwdriver. Remove the caseback and the battery sticker.
Use a small, flat tool to open the latch (5) of the battery holder. Remove the
battery and insert a fresh 3V CR2032 battery with the (+) terminal facing upwards.
Ensure that the gasket (6) is seated correctly. Close the latch of the battery holder.
Replace the battery sticker and the caseback and replace the screws.
Battery low indicator
If the battery voltage on the chest belt battery drops below the voltage required for
normal operation,
TXBELT
LO BAT
TXGURT
BATT
SNGLTX
PILE
TXBCIN
BAT BA
will appear on the display. Replace the battery of the chest belt as described in the
chapter "Chest belt".