beautypg.com

Kichler 43403 User Manual

Kichler Lighting

background image

1) Align hole in top of top arm with hole in cup at top of center stem.

2) From inside cup, thread ball stud through hole in cup and into hole in

top of arm. Tighten ball stud to secure arm in place.

3) Repeat steps 1 and 2 for remaining arms.

4) Lower end of threaded pipe down into cup on top of center tube. Screw

end of threaded pipe into hex coupling inside cup.

5) Pass hole in top trim down over end of threaded pipe and set top trim

on top of cup.

6) Screw loop onto end of threaded pipe protruding from top of top trim.

7) Thread hexnut onto one end of short threaded pipe approximately 1/2” down

from end.

8) Slip flat washer then rubber washer over end of threaded pipe.

9) From inside glass, slip long end of threaded pipe through hole in glass.

10) Slip rubber washer then flat washer over end of threaded pipe protruding

from bottom of glass. Thread hexnut on to threaded pipe.

11) Slip bottom trim over threaded pipe. Thread finial onto end of threaded

pipe. (DO NOT over tighten.)

12) Insert recommended bulb.

13) Raise glass up to fixture. Align holes in glass with holes in end of arms.

14) Insert ball studs through holes in glass and thread ball studs into holes

in arms. Tighten ball studs to secure glass in place. (DO NOT over

tighten.)

15) TURN OFF POWER.

IMPORTANT: Before you start, NEVER attempt any work without

shutting off the electricity until the work is done.

a) Go to the main fuse, or circuit breaker, box in your home. Place

the main power switch in the “OFF” position.

b) Unscrew the fuse(s), or switch “OFF” the circuit breaker switch(s),

that control the power to the fixture or room that you are working on.

c) Place the wall switch in the “OFF” position. If the fixture to be

replaced has a switch or pull chain, place those in the “OFF”

position.

16) Take threaded pipe from parts bag and screw in screw collar loop a

minimum of 6 mm (1/4”). Lock into place with hexnut.

17) Run another hexnut down threaded pipe almost touching first hexnut.

Now screw threaded pipe into mounting strap. Mounting strap must be

positioned with extruded thread faced into outlet box. Threaded pipe

must protrude out the back of mounting strap. Screw third hexnut onto

end of threaded pipe protruding from back of mounting strap.

18) Connect mounting strap to outlet box.

19) Unscrew the threaded ring from screw collar loop. Take canopy and

pass over screw collar loop. Approximately one half of the screw collar

loop exterior threads should be exposed. Adjust screw collar loop by

turning assembly up or down in mounting strap. Remove canopy.

20) After desired position is found, tighten both top and bottom hexnuts up

against the bottom and top of the mounting strap.

21) Slip canopy over screw collar loop and thread on threaded ring. Attach

chain (with fixture connected) to bottom of screw collar loop. Unscrew

threaded ring, let canopy and threaded ring slip down.

22) Weave electrical wire and ground wire through chain links no more than

3 inches apart. Pass wire through threaded ring, canopy, screw collar

loop, threaded pipe and into outlet box.

23) Grounding instructions: (See Illus. A or B).

A) On fixtures where mounting strap is provided with a hole and two

raised dimples. Wrap ground wire from outlet box around green

ground screw, and thread into hole.

B) On fixtures where a cupped washer is provided. Attach ground

wire from outlet box under cupped washer and green ground

screw, and thread into mounting strap.

If fixture is provided with ground wire. Connect fixture ground wire to

outlet box ground wire with wire connector (not provided.) after following

the above steps. Never connect ground wire to black or white power

supply wires.

24) Make wire connections (connectors not provided). Reference chart

below for correct connections and wire accordingly.

25) Raise canopy to ceiling.

26) Secure canopy in place by tightening threaded ring onto screw collar

loop.

MOUNTING STRAP

ABRAZADERA DE MONTAJE

HEXNUT

TUERCA

HEXAGONAL

THREADED PIPE

TUBO ROSCADO

SCREW COLLAR LOOP

OJAL DE COLLAR

ROSCADO

CANOPY

ESCUDETE

THREADED RING

ANILLO ROSCADO

Date Issued: 8/26/11

IS-43403-US

GREEN GROUND

SCREW

CUPPED

WASHER

A

B

OUTLET BOX

GROUND

FIXTURE

GROUND

DIMPLES

WIRE CONNECTOR

(NOT PROVIDED)

OUTLET BOX

GROUND

GREEN GROUND

SCREW

FIXTURE

GROUND

Connect Black or

Red Supply Wire to:

Connect

White Supply Wire to:

Black

White

*Parallel cord (round & smooth)

*Parallel cord (square & ridged)

Clear, Brown, Gold or Black

without tracer

Clear, Brown, Gold or Black

with tracer

Insulated wire (other than green)

with copper conductor

Insulated wire (other than green)

with silver conductor

*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)

Neutral Wire

LOOP

ANILLO

GLASS

VIDRIO

THREADED PIPE

TUBO ROSCADO

ARM

BRAZO

SHORT THREADED

PIPE

TUBO ROSCADO

CORTO

CENTER STEM

VÁSTAGO CENTRAL

HEXNUT

TUERCA HEXAGONAL

BALL STUD

ESPÁRRAGO DE

CABEZA ESFÉRICA

CUP

TAZA

TOP TRIM

ASIENTO SUPERIOR

BALL STUD

ESPÁRRAGO DE

CABEZA ESFÉRICA

RUBBER WASHER

ARANDELA DE CAUCHO

FLAT WASHER

ARANDELA PLANA

BOTTOM TRIM

GUARNICIÓN INFERIOR

FINIAL

CAPUCHON

HEXNUT

TUERCA HEXAGONAL

RUBBER WASHER

ARANDELA DE

CAUCHO

FLAT WASHER

ARANDELA

PLANA

SEE OTHER SIDE FOR SPANISH TRANSLATIONS.

VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.

This manual is related to the following products: