MOUNTING STRAP

ABRAZADERA DE MONTAJE

LOOP/CHAIN LINK MOUNT INSTALLATION INSTRUCTIONS

1) Pass wire from fixture through stem and screw stem to top of fixture.

NOTE: Thread locking compound must be applied to all stem threads

as noted with symbol (3) to prevent accidental rotation of fixture during

cleaning, relamping, etc.

2) Pass fixture wire through remaining stems and screw stems together.

3) Thread one small threaded pipe into end of each small loop.

4) Attach small loop to end of last stem.

5) Pass threaded pipe at end of second small loop through hole in canopy.

6) Slip lockwasher over threaded pipe protruding from inside of canopy

and screw hexnut onto threaded pipe.

7) Attach chain link to small loop at end of stem and to loop on canopy.

8) TURN OFF POWER.

IMPORTANT: Before you start, NEVER attempt any work without

shutting off the electricity until the work is done.

a) Go to the main fuse, or circuit breaker, box in your home. Place

the main power switch in the “OFF” position.

b) Unscrew the fuse(s), or switch “OFF” the circuit breaker switch(s),

that control the power to the fixture or room that you are working on.

c) Place the wall switch in the “OFF” position. If the fixture to be

replaced has a switch or pull chain, place those in the “OFF”

position.

9) Find the appropriate threaded holes on mounting strap. Assemble

mounting screws into threaded holes.

10) Attach mounting strap to outlet box. (Screws not provided). Mounting

strap can be adjusted to suit position of fixture.

11) Grounding instructions: (See Illus. A or B).

A) On fixtures where mounting strap is provided with a hole and two

raised dimples. Wrap ground wire from outlet box around green

ground screw, and thread into hole.

B) On fixtures where a cupped washer is provided. Attach ground

wire from outlet box under cupped washer and green ground

screw, and thread into mounting strap.

If fixture is provided with ground wire. Connect fixture ground wire to

outlet box ground wire with wire connector. (Not provided.) After following

the above steps. Never connect ground wire to black or white power

supply wires.

12) Make wire connections (connectors not provided.) Reference chart below

for correct connections and wire accordingly.

13) Push fixture to ceiling, carefully passing mounting screws through holes

in canopy.

14) Secure fixture to ceiling with knurl knobs.

15) Insert recommended bulbs.

16) Lower stepped end of bracket down to fixture plate on top of socket

cluster. (See Fig. A for proper position of bracket.)

17) Align hole in bracket with hole in fixture plate.

18) Thread ball stud into hole in bracket and into fixture plate. Tighten ball

stud to secure bracket to fixture plate. (DO NOT over tighten.)

19) Repeat steps 16-18 for remaining brackets.

20) Set glass down into ring.

21) Raise ring with glass up to fixture. Brackets will fit inside ring.

22) Align holes in ring with holes in brackets.

23) Thread thumbscrews into holes in ring and into brackets. Tighten

thumbscrews to secure ring to brackets. (DO NOT over tighten.)

RIGID STEM MOUNT INSTALLATION INSTRUCTIONS

1) Pass wire from fixture through stem and screw stem to top of fixture.

NOTE: Thread locking compound must be applied to all stem threads

as noted with symbol (3) to prevent accidental rotation of fixture during

cleaning, relamping, etc.

2) Pass fixture wire through remaining stems and screw stems together.

3) Thread short threaded pipe into end of last stem.

4) Pass hole in canopy over end of stem.

5) Slip one lockwasher over end of stem protruding from inside canopy.

Screw hexnut onto stem.

6) Follow steps 8-23 in Loop/Chain Link Installation Instructions.

GREEN GROUND

SCREW

CUPPED

WASHER

A

B

OUTLET BOX

GROUND

FIXTURE

GROUND

DIMPLES

WIRE CONNECTOR

(NOT PROVIDED)

OUTLET BOX

GROUND

GREEN GROUND

SCREW

FIXTURE

GROUND

Connect Black or

Red Supply Wire to:

Connect

White Supply Wire to:

Black

White

*Parallel cord (round & smooth)

*Parallel cord (square & ridged)

Clear, Brown, Gold or Black

without tracer

Clear, Brown, Gold or Black

with tracer

Insulated wire (other than green)

with copper conductor

Insulated wire (other than green)

with silver conductor

*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)

Neutral Wire

Date Issued: 7/30/12

IS-42244-US

CANOPY

ESCUDETE

STEM

VÁSTAGO

KNURL KNOB

PERILLA ESTRADA

3

SMALL LOOP

ARGOLLA PEQUEÑA

3

GLASS

VIDRIO

CHAIN LINK

ESLABÓN DE CADENA

RING

ANILLO

THUMBSCREW

TORNILLO DE

MARIPOSA

SEE OTHER SIDE FOR SPANISH TRANSLATIONS.

VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.

RIGID STEM MOUNT

MONTAJE DEL VÁSTAGO NERVADO

LOOP/CHAIN LINK MOUNT

MONTAJE DE LAZO/ ESLABÓN DE CADENA

BALL STUD

ESPÁRRAGO

DE CABEZA

ESFÉRICA

BRACKET

PEDESTAL

FIXTURE PLATE

PLACA DEL ARTEFACTO

STEPPED END

EXTREMO ESCALONADO

DEL PEDESTAL

STEM

VÁSTAGO

HEXNUT

TUERCA HEXAGONAL

LOCKWASHER

ARANDELA DE

SEGURIDAD

FIG. A