Kichler 15073 User Manual
Kichler Lighting
INSTRUCTIONS PERTAINING TO A RISK OF FIRE,OR INJURY TO
PERSONS
IMPORTANT SAFETY INSTRUCTIONS
Lighted lamp is HOT!
WARNING — To reduce the risk of FIRE OR INJURY TO PERSONS.
1) Turn off / unplug and allow to cool before replacing lamp.
2) Lamp gets HOT quickly! Contact only switch / plug when turning on.
3) Do not touch hot lens or cowl.
4) Do not remain in light if skin feels warm. (Light is intense, it may cause
“sunburn”.)
5) Do not look directly at lighted lamp.
6) Keep lamp away from materials that may burn.
7) Use only with wattage and lamp marked on fixture.
8) Do not touch the inner glass envelope of the lamp at any time. Use a soft
cloth. Oil from skin may damage lamp.
9) Do not operate the fixture with a damaged or missing lens.
SAFETY INSTRUCTIONS
READ THIS FIRST
KEEP THESE INSTRUCTIONS
This fixture is intended for installation in accordance with the National
Electric Code (NEC) and Local code specifications. Failure to adhere to
these codes and instructions may result in serious injury and/or property
damage and will void the warranty.
1) WARNING: This fixture is not to be installed within 10 feet (3M) of a pool,
spa or fountain.
2) This fixture is to be used only with a power unit (transformer) rated a
maximum of 300 W (25 AMPS) 15 volts.
3) The #18 ga. fixture wire is not intended for direct burial.
4) Direct burial rated wire is to be buried a minimum of 6” (152mm) beneath
the surface of the ground.
NOTE: If additional Direct Burial wire is needed, contact your local Kichler
®
landscape distributor.
• 8 GA wire can be purchased in length of 250’ (76 M), 15503-BK.
• 10 GA wire can be purchased in length of 250’ (76 M), 15504-BK.
• 12 GA wire can be purchased in lengths of 100’ (30 M), 15501-BK; 250’
(76 M), 15502-BK; 500’ (152M), 15505-BK; and 1000’ (304 M), 15506-BK.
5) Fixture shall not use a tungsten halogen lamp unless the fixture is marked
for use with such lamps.
6) Wiring connections must be made with approved/listed wire connection
device(s) suitable for the application. Do not exceed manufacturers’ wiring
combination specifications for size and quantity of conductors.
For warranty information please visit: http://www.landscapelighting.com/portal/warranty_page
Para informacion de la garantia por favor visite: www.landscapelighting.com/portal/warranty_page
Date Issued: 12/2/11
IS-15073-US
QUIC DISC
™
WIRING INSTRUCTIONS
Turn off power.
The full length of the 18 GA fixture wire may be used to connect with the 10 GA or 12 GA cable provided the following conditions are met:
• Wiring is to be protected by routing close to the fixture or accessory or secured to a building structure such as house or deck.
• 18 GA fixture wiring is to be cut off so that it is attached to the connector within 6 inches of the fixture or building structure.
• If it is necessary to make the connections underground, then no more than 6 inches of the 18 GA fixture wire is to be buried.
The Quic Disc
™
connector is designed to install one fixture and accommodates one 18 GA fixture wire and one 10 GA or one 12 GA supply wire.
Place the 10 gauge supply wire across the area marked 10 GA on Quic Disc
™
or place the 12 gauge supply wire across the area marked 12 GA
on Quic Disc
™
.
Place the 18 gauge fixture wire across the area marked 18 GA on the Quic Disc
™
. After the wires are in place, connecta the top of the Quic
Disc
™
to the base with supplied screw, making sure that the wires remain flat in the bottom portion of the Quic Disc
™
, and the screw is tightened
all the way down.
The copper contacts will automatically pierce the wires’ insulation. Excess 18 GA fixture wire that sticks out the end of the Quic Disc
™
is to be cut off.
Make no other wiring connections to the 18 GA fixture wire.
SAVE THESE INSTRUCTIONS
INSTALLATION AND ASSEMBLY
Before Starting:
A) Desired location for each fixture should be determined before
construction of wall is started.
B) If access to back of wall is limited, cable/conduit should be run prior to
construction.
1) TURN OFF POWER.
2) Assemble brackets to bottom of housing using washers and screws.
3) Knock off corner of brick on either side or below housing for cable/conduit
entry and exit.
4) Screw supplied 1/2 NPT plugs into holes in housing not being used for
wire passage.
5) Remove socket bracket from inside of housing.
6) Mortar housing into place noting the following items:
A) Supply wire may need to be run into housing at this time, if so pull supply
wire through appropriate hole in housing and secure cable/conduit to
housing using a suitable connector.
B) Embed lower brackets in mortar.
C) Mortar housing into place as it if were a brick.
D) Allow mortar to cure before wiring and re-assembling brick light.
7) Continue building wall, installing remaining housing as specified above.
NOTE: Before the coarse of brick over housing is laid, attach brackets to top
of housing using washers and screws.
CAUTION: When securing brackets, do not apply a lot of pressure or force.
This may damage uncured mortar.
8) Allow wall to cure.
9) Make wire connections (connectors not provided.) This fixture uses a
non-polarized socket. Each supply wire may be connected to either fixture
wire.
10) Push socket bracket into housing and secure in place with screws.
11) Insert recommended lamps.
12) Assemble cover/lens to housing.
WASHER
ARANDELA
SCREW
TORNILLO
COVER/LENS
TAPA/LENTE
SOCKET BRACKET
APOYO DEL ENCHUFE
BRACKET
APOYO
SCREW
TORNILLO
HOUSING
CUBIERTA