beautypg.com

Introduction – Empire Comfort Systems BVD36FP32 User Manual

Page 5

background image

Page 5

19400-3-0406

Instructions to Installer

1. Installer must leave instruction manual with owner after

installation.

2. Installer must have owner fill out and mail warranty card

supplied with the fireplace.

3. Installer should show owner how to start and operate the

fireplace.

This is a B-Vent gas appliance and must be installed with a listed

B-Vent vent system. The information contained in this manual

pertains to all models and gas control systems unless otherwise

noted.

Warning: This unit is not for use with solid fuels.

Appliance Certification

This fireplace is design certified in accordance with American

National Standard/CSA Standard ANSI Z.21-50/CSA 2.22 and by

Underwriters Laboratories as a Vented Gas Appliance and shall be

installed according to these instructions.
Consult your local building code agency, prior to installation,

to ensure compliance with local codes-including permits and

inspections.
The fireplace, when installed, must be electrically grounded in

accordance with local codes or, in absence of local codes, with

the National Electric Code ANSI/NFPA 70 if an external electrical

source is utilized.
These models may be installed in a bedroom or bed-sitting room

in the U.S.A.
Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment

or accessories and repair and servicing of equipment shall be

performed only by a qualified agency. The term “qualified agency”

means any individual, firm, corporation or company which either in

person or through a representative is engaged in and is responsible

for (a) the installation or replacement of gas piping or (b) the

connection, installation, repair or servicing of equipment, who is

experienced in such work, familiar with all precautions required

and has complied with all the requirements of the authority having

jurisdiction.

State of Massachusetts: The installation must be made

by a licensed plumber or gas fitter in the Commonwealth

of Massachusetts. The state of Massachusetts requires that

a flexible appliance connector cannot exceed three feet in

length.

The installation must conform with local codes or, in the absence of

local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA

54* Natural Gas and Propane Installation Code, or CSA B149.1

in Canada.

*Available from the American National Standards Institute, Inc. 11

West 42nd St., New York, N.Y. 10036.

Warning: ANY CHANGE TO THIS FIREPLACE OR ITS

CONTROLS CAN BE DANGEROUS.

Improper installation or use of the fireplace can cause serious

injury or death from fire, burns, explosions, or carbon monoxide

poisoning.

Any alteration of the original design, installed other than

as shown in these instructions or use with a type of gas not

shown on the rating plate is the responsibility of the person

and company making the change.

Important

All correspondence should refer to complete Model Number,

Serial Number and type of gas.
High Altitude

When installing this unit at an elevation above 2000 feet (in the

United States) it may be necessary to decrease the input rating by

changing the existing burner orifice to a smaller size. Generally,

input should be reduced 4 percent for each 1000 feet above sea

level. However, if the heating value of the gas has been reduced,

this general rule may not apply. Check with local gas utility for

proper orifice size identification.
Canadian High Altitude

Altitude: 0-4500 feet (0-1370 m)
When installing this unit at an elevation above 4500 feet (in

Canada), check with local authorities.
Consult your local gas utility for assistance in determining the

proper orifice for location.
Preparation

This gas fireplace and its components are tested and safe when

installed in accordance with this Installation Manual. Report to

your dealer any parts damaged in shipment, specifically check

glass condition. Do not install unit with damaged, incomplete, or

substitute parts. Read all instructions before starting installation

and follow these instructions carefully during installation to insure

maximum benefit and safety. Failure to follow them will void your

warranty and may present a fire hazard.
The warranty will be voided by, and the warrantor disclaims any

responsibility for the following actions:

• Installation of any damaged fireplace or vent system

component.

• Modification of the fireplace or vent system.

• Installation other than as instructed by Empire Comfort Systems,

Inc.

• Improper positioning of the logs, glass door, optional accessories

or decorative rock.

• Installation and/or use of any component part not manufactured

or approved by manufacturer.

Glass Specifications

Optional glass door kits manufactured with tempered glass

may be installed in hazardous locations such as bathtub

enclosures as defined by the Consumer Product Safety Commission

(CPSC). The tempered glass has been tested and certified to the

requirements of ANSI Z97.1 and CPSC 16 CFR 1202

(Safety Glazing Certification Council SGCC# 1595 and 1597.

Architectural Testing, Inc. Reports 02-31919.01 and

02-31917.01).
This statement is in compliance with CPSC 16 CFR Section

1201.5 "Certification and labeling requirements" which refers

to 15 U.S. Code (USC) 2063 stating "...Such certificate shall

accompany the product or shall otherwise be furnished to any

INTRODUCTION

This manual is related to the following products: