Elation Professional Work Light User Manual
Page 42
Platinum Spot LED™
©Elation Professional, Los Angeles Ca.
42
www.ElationLighting.com
defective motor IC drive on the main PCB).
Color-wheel error:
The color wheel is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the color wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
Rotating gobo-wheel error:
The gobo-wheel is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the gobo wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
Rotating gobo indexing error:
The gobo is not located in the default position after start-up or after a reset command. This
message will appear after a fixture reset if the gobo positioning magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
Fix Gobo-wheel error:
This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive
circuit on the main PCB). The fix gobo wheel is not located in the default position after the
reset.
Iris error:
This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driver circuit on the main PCB). The Iris wheel is not located in the default position after the
reset.