Cabling

4

1/1531-HSD 101 41 Uen A 2004-01-30

3 Cabling

3.1

Cabling of Subscriber Lines

Before the IP DSLAM is mounted the connections between the Line MDF
and the Exchange MDF have to be rewired. The wires are disconnected,
and then reconnected through typically a Broadband MDF and the EDA
System according to planning.

3.1.1 Cabling

Lines

The following description explains how to rewire the connections between
the Line MDF and Exchange MDF through the EDGE connectors.

Figure 2 on page 4 shows the subscriber line connections through the
EDGE connectors both for exchange and line side.

Exchange EDGE Connector

Line EDGE Connector

Line J

Line L

Line K

Line I

Line H
Line G

Line F
Line E
Line D
Line C

Line B
Line A

Subscriber L
Subscriber K

Subscriber J

Subscriber I

Subscriber H
Subscriber G

Subscriber F

Subscriber E
Subscriber D

Subscriber C
Subscriber B

Subscriber A

12 Subscriber Lines

to the Line MDF

12 Lines to the Exchange

MDF

Figure 2

Rewiring the Subscriber Line through EDGE Connectors