9.3.1

Fitting and changing the saw blade

Caution! Unplug from power source.

Caution! Ensure that the saw housing is well lit.

 Remove the two screws of the table insert
 Remove the table insert
 Use the crank and turn to the left to bring the saw blade as far up as it will go.
 Use the wrenches (19-20) to undo the screws on the saw blade (Fig. 8) and exchange the

blade with a suitable replacement. Watch the direction of operation! See the arrow on the
saw blade. The teeth must point towards the on/off switch (1).

9.3.2

Adjusting the cleaving wedge

The gap between the external edge of the saw blade and the cleaving wedge (7) must be
between three and eight millimetres.
 Bring saw blade to the 0° position and tighten.
 Bring the saw blade into the upper position.
 Remove the saw blade protector.
 Remove the table surface.
 Loosen the screw (A) slightly with a suitable combination wrench until the cleaving wedge

(7) is released (do not remove screw)

 Set the cleaving wedge lower or higher by pushing upward or downward in the long hole.
 Mount all dismantled parts in reverse sequence.

10 STORAGE, TRANSPORTATION

10.1

Storage

Risk of injury! Store the unit in such a way that it cannot be started by
unauthorised persons. Ensure that no one is able to injury themselves on
the stored unit.

Machine damage! Do not store unprotected in a damp environment.

10.2

Transportation

Note: Only lift the unit using the handles.

 Crank the saw blade down as far as it will go.
 Parts that extend beyond the saw should be removed.
 Transport the unit with the assistance of another person and use the handles.
 When dispatching, try to use the original packaging, if possible.