Adjust the motion sensor to cover the desired detection area.
For a smaller coverage area, point the sensor down; for a larger coverage area, point 
the sensor up. 
7.2 TIME adjustment 
 
The TIME adjustment controls how long the floodlight will stay on after the motion 
has been detected. 
Turn the TIME control knob clockwise to increase (up to about 12 minutes) how long 
the floodlights stay on or anti-clockwise to decrease (down to about 5 seconds) the 
time delay. 
7.3 LITE adjustment 
 
The LITE adjustment determines at what light level the lighting system will start 
operating when you set the sensor to Automatic Operation. 
Provisionally turn the LITE control knob to the edge clockwise at the moon (dusk) 
position. In this provisional setting mode, the motion sensor remains inactive during 
daylight. At dusk when you find it is the LUX level desired for operation, simply set 
the LITE control knob to the position that the motion sensor will become active as 
daylight declines. 
7.4 SENS. adjustment 
The sensitivity adjustment may be adjusted to compensate for seasonal variations in 
temperature and to reduce unwanted triggering. The optimum sensitivity can be achieved 
by setting the SENS. control knob initially to its mid-point and then adjusting the control 
knob clockwise to increase (up to 12 meters) the detecting distance or anti-clockwise to 
decrease (down to 3 meters) the detecting distance. 
8
THE FIELD OF DETECTION
The field of detection of the infrared lamp can be adjusted 30degree in horizontal 
direction and 30 degree in vertical direction. By means of horizontal adjustment, the 
permanent 180°field of detection can be infinitely directed to the right or left 
(Fig.4).By means of vertical adjustment the detection range can be reduced or 
expanded (Fig.5).This way any false detections caused by movements from 
neighbours and from the street are excluded. 
The best detection is obtained by approaching the field of detection perpendicular to 
its axis (Fig.6). 
If the field of detection is approaching the direction of its axis, the infrared detector 
will, in some cases, respond later (Fig.7) 
9
FIXING AND CHANGING A HALOGEN TUBE
Lamp tube fitting. Unscrew the bolt and open the glass holder. Fit the tube into the 
tube socket. Assure that the two ends of the tube contact the socket pole correctly. 
Then place the waterproof rubber pad in it’s original position and close the cover with 
the bolt. 