36
Input Circuits
HP289
6. Input Circuits
This section covers the connection of flowmeter signals for the Model
214D Series Batch Controllers.
The 214D Series has a regulated power supply output which can be
used to power sensors. A trimpot on the rear of the instrument allows
the voltage to be adjusted in the range of 8-24 Volts and the output can
supply a maximum of 50mA.
6.1 Input Circuit for the 214D Series
The 214D Series has an input conditioning card which will accept
signals from most pulse or frequency producing flowmeters. An 8
position DIP switch on the rear panel enables the input circuit to be
configured for different signal types.
The input will interface directly to:
•
Turbine Flowmeters
•
Open Collector Outputs
•
Reed Switches
•
Logic Signals
The following pages give examples of the interconnection to various
signal outputs and a circuit diagram of the input is also provided.
- C8230 (29 pages)
- 400 (38 pages)
- 400 (148 pages)
- 600 (135 pages)
- 640 (45 pages)
- 700 (10 pages)
- 850 (147 pages)
- 1520 (40 pages)
- C82314 (71 pages)
- RS-485 (2 pages)
- 6200A (97 pages)
- C82307 (37 pages)
- UB E02 (86 pages)
- 440 (240 pages)
- 440 (212 pages)
- 660 (92 pages)
- 5000 (154 pages)
- 5000 (176 pages)
- 9000 (68 pages)
- ARM.POWERED ARM720T (224 pages)
- SD-DSPUSBB (2 pages)
- CMD-2260 (18 pages)
- C823301 (17 pages)
- S1C6200A (98 pages)
- 33+ (10 pages)
- FEH300b (46 pages)
- SED 1520 Series (40 pages)
- Serial Interface GQ-3500 (13 pages)
- ETX-945 (39 pages)
- Photo EX (35 pages)
- C82364 (279 pages)
- EM07ZS1647F (168 pages)
- Connect-It SD-DSWIFIB (2 pages)
- ACTIONPC 7000 (10 pages)
- S5U1C63000H2 (35 pages)
- C824 (4 pages)
- C82069* (46 pages)
- 80211b (68 pages)
- C82312 (13 pages)
- S5U1C17801T1100 (60 pages)
- C82324* (57 pages)
- C82372 (22 pages)
- C82315 (48 pages)
- P07303 (36 pages)