36

Input Circuits

HP289

6. Input Circuits

This section covers the connection of flowmeter signals for the Model
214D Series Batch Controllers.

The 214D Series has a regulated power supply output which can be
used to power sensors. A trimpot on the rear of the instrument allows
the voltage to be adjusted in the range of 8-24 Volts and the output can
supply a maximum of 50mA.

6.1 Input Circuit for the 214D Series

The 214D Series has an input conditioning card which will accept
signals from most pulse or frequency producing flowmeters. An 8
position DIP switch on the rear panel enables the input circuit to be
configured for different signal types.

The input will interface directly to:

Turbine Flowmeters

Open Collector Outputs

Reed Switches

Logic Signals

The following pages give examples of the interconnection to various
signal outputs and a circuit diagram of the input is also provided.