Configuration

29

HP289

5.1 Configuring the Setup Parameters

Step

Display

Description

Text

Ref

1

CAL

Setup Program Parameters

BATCH

Set Batch Parameters

5.2

OPTION Options (if installed)

5.3

TEST

Check Input Signals

5.4

END

Exit to normal operation

The following steps are displayed when CAL is selected.

2

RESTOT Reset all totals to zero.

To clear all totals (resettable and
accumulated) press the BATCH SET key
once.

3

SCALE

Scaling Factor.

Fact

Enter the Scaling factor (K-factor) of the
flowmeter.

3.3.1

4

F dPt

Number of decimal points with which the Rate
is to be displayed between 0 to 0000.

5

t.base

The Timebase with which the Rate is
calculated must be entered as:

3.2.1

60secs

units/min

hours

units/hour

days

units/day

secs

units/second

6

FILTER The filter constant for filtering the rate display. 3.3.2

1

No filtering.

to

99

Very heavy filtering.

7

TOTCON A division factor to convert the totals to

different units from those used for rate (e.g.,
gallons/min and barrels).

3.30

1

Rate and totals have the same engineering
units.

x.xxxx

Other factors can be programmed between
0.01 and 2000.

8

t.dPt

Number of decimal points with which the
resettable total is displayed between 0 to 00.