You may see one of the following error messages during this test:

E r r o r - P r i n t e r O u t o f P a p e r
E r r o r - P r i n t e r N o t S e l e c t e d

E r r o r - P r i n t e r I n t e r f a c e I / O E r r o r
E r r o r - T i m e O u t O n P r i n t e r

Check that the printer is on-line, paper is loaded, and all
connections are secure.

Communication Adapter Test

This test checks the serial port. Before running this test, you

must connect a special RS-232C connector to the serial port.

The connector requires the following settings:

RD and TD shorted

DSR and DTR shorted 4 - 6

CTS and RTS shorted

7 - 8

You can purchase an AT-type loopback connector from most

electronic supply stores. This connector allows the test to send
out and receive the same data for the purpose of the test.

This test checks the serial port for the following parameters:

9600 baud rate

Odd parity

2 stop bits

8-bit data length

This test first performs a reset function to check for all possible

errors. Then it performs a send function followed by a receive.

System Diagnostics 39