Magnum Energy ME-ARC Remote User Manual
Page 2
![background image](https://www.manualsdir.com/files/821299/content/doc002.png)
Magnum Energy, Inc.
PN: 64-0030-030 Rev C
Page 2 of 2
≥Level 1 [1]
MSH-RE Models
≥Level 1
Absorb (12.0-16.0)
14.6
Float (12.0-16.0)
13.4
EQ (12.0-16.0)
15.5
≥Level 2
≥Level 3
US Models
MSH-RE Models
Export Models
≥Level 4 [5]
≥Level 4 [6]
≥Level 4 [6][7]
03F Max Charge Time
≥Level 4 [6]
03G Final Charge Stage
≥Level 4 [6]
04F Max Gen Run Time
≥Level 1
04I Gen Warm-up Time
≥Level 1
04J Gen Cooldown Time
≥Level 1
05A Charge Eff
≥Level 1 [7]
05B AmpHour Size
≥Level 1 [7]
03C Max Charge Rate
100%
03 Charger
Setup
SETUP
≥Level 3 [2]
Auto
400 AH
≥Level 4
≥Level 1 [7]
60 Sec
OFF
OFF
OFF
12.0 Hrs
≥Level 1
≥Level 1
≥Level 1
≥Level 1
≥Level 1
60 Sec
OFF
OFF
OFF
12.0 Hrs
Multi
11.5
120 Sec
14.4
120 Sec
20A
30A
80 VAC
75 VAC
Run Time= 0.0-25.5 hours
Flooded:
150 VAC
2.0 Hrs
Stop Gen AC Amps= 5-60A
0-127 sec, 1-127 min
0-127 sec, 1-127 min
Auto, 50-97%
200-2500 AH
Quiet Time Topoff= OFF, 30-120Min
OFF, 0.1-25.5 Hrs
OFF, ON= Start Quiet Time= 12:00A-12:00P
Stop Quiet Time= 12:00A-12:00P
Days= OFF, 1-255 days
Run Hour/Min/AM-PM= 12:00A-12:00P
Stop Amps Delay= 0-127 sec, 1-127 min
OFF, Start Gen SOC= 20-90%
Stop Gen SOC= 21-100%
Start= OFF,
Ext Input, 65-95F (18-35C)
Time= 0.5-6.0 Hrs
Stop Gen Volts= 9.1-16.0*, Float
Stop Volts Delay= 0-127 sec, 1-127 min
OFF, ON= Start Gen Time= 12:00A-12:00P
Stop Gen Time= 12:00A-12:00P
Start Gen AC Amps= OFF, 5-60A
Time= 0.1-25.5 Hrs
10-100%
Start Amps Delay= 0-127 sec, 1-127 min
Amps= 0-150 ADC
SOC= 50-100%
0.0-25.5 hours
Multi, Float, Silent
Start Gen Volts= 9.0-15.9*
Start Volts Delay= 0-127 sec, 1-127 min
0-100%
AC/AC1 Input= 60-100 VAC, UPS Mode
AC2 Input= 60-100 VAC
110-190 VAC, UPS Mode
Custom
Gel,
Flooded,
AGM,
AGM2
03B Battery Type
AC/AC1 Input= 5-60A
03E Absorb Done
04A Gen Run VDC
03A AC Input Amps
03D VAC Dropout
04 AGS Setup
05 BMK Setup
04E Gen Run Temp
04H Gen Exercise
04G Quiet Time
04B Gen Run Time
04C Gen Run Amps
04D Gen Run SOC
AC2 Input= 5-60A [F]
* 12-volt values shown; for 24-volts systems - multiply by 2 and for 48-volt systems - multiply by 4.
** These settings return to the factory default setting when power to the remote is removed.
[F] Features added to Rev 3.0/3.01. Also added: Recording AGS fault history, clearing inverter/AGS faults, and
displaying Load Support statuses.
ME-ARC (Rev 3.0/3.01) Compatibility Matrix Notes:
[1] Will not work with MM/MM-E/MM-AE/MMS/MMS-E models.
[2] AC Couple Mode activates when Battery Type = Custom with MS-PAE Series ≥Rev 4.1 or MS/MS-PE series ≥5.0.
[3] The AC output volts are accurate only when used with MS, MS-PE, MS-PAE or MSH Series inverters.
[4] The AC amps displays are not shown unless connected to MS-PE, MS-PAE or MSH Series inverters.
[5] Level 2 and 3 inverters can be used, but:
Level 2 inverters are limited from 1.0 hour to 4.5 hours,
Level 3 inverters
Any setting outside these limited ranges is not recognized and reverts to the inverter's default absorption time
(2.0 hours).
[6] Requires ≥Level 4 to display.
[7] SOC features require the ME-BMK (Battery Monitor Kit) to be installed.
[8] To manually turn the generator "ON" with the remote, ME-AGS-N rev 5.0 or higher is required.