Magnum Energy ME-MW-W User Manual
Page 8

4
© 2011 Magnum Energy, Inc.
2.0 Installation
2.1 Required Components and Tools
2.1.1 List of Supplied Components in the MagWeb Kit
• ME-MW-W Owner’s Manual
• MagWeb device (with two #8 x 3/4” Phillips mounting screws)
• MagWeb wireless gateway
• 6ft four-conductor communications cable
• 6ft eight-conductor CAT5 Ethernet cable
• AC to DC adapter for wireless gateway
• 2.4 GHz rubber duck antennas, one for the MagWeb device and one
for the wireless gateway
Info: The four-conductor communications cable is a twisted-
pair, telephony standard with RJ11 connectors on each end. A
standard telephone cable may be substituted if the supplied
remote cable cannot be used.
The eight-conductor CAT5 Ethernet cable is a standard twisted-
pair cable with RJ45 connectors on each end. A standard CAT5
Ethernet cable up to 100 meters may be substituted if the
supplied Ethernet cable cannot be used.
2.1.2 List of Other Required Equipment and Materials
• Magnum inverter with a Network port
• ‘Always on’ internet connection that can support 2.5 megabytes per
day outgoing data and allows connection to a public internet host
2.1.3 Tools Required to Install the MagWeb Kit
• #2 Phillips screwdriver
2.2 Setting Up the MagWeb Device
Mount the MagWeb device in a location that is dry and away from extreme
temperatures. Use the two supplied #8 x 3/4” screws to securely affi x the
module. Allow ample room to view the MagWeb device’s LED, to access the
two RJ11 ports, and to connect the antenna. Unless the wireless gateway will
be located in the same room, you must keep the MagWeb device’s antenna
outside of a metallic enclosure or compartment.
CAUTION: Do not mount the MagWeb device in a closed battery
compartment, or in an area where water or any other liquid
can enter the device and cause shorting or corrosion. Failure
due to improper mounting is not covered by the warranty.
CAUTION: Before beginning the installation, ensure all AC
power is disconnected from the inverter, and all battery supply
cables are disconnected from the battery bank or switched
off with an appropriately rated circuit breaker. There should
be no fl ashing or lit LEDs on the Magnum inverter or on any
accessories.