Page 9

Clear the grid-feed counter

When you clear the grid-feed counter, all counters (Counter yield and

Counter oper. hours) are reset to zero.

To clear the counters, select “Yes” with key “2”, and confirm your

selection by pressing the “1” key. The required code is “2” and is ente-

red using key “2”. By means of an additional confirmation with key

“1”, all counter are cleared. The display “Grid-feed counter cleared!”

confirms that the counters have been cleared.

“Counter yield” and “Counter oper. hours” can be cleared separately from

the other counters. These counters are cleared in the configuration menu

using key 2 and the code 2. ”Counter yield” and “Counter oper. hours” are

always cleared together.

Define the initial value of the total yield

Use this menu setting to define or reset the intial value of the total

yield of the inverter.

Select the Interface and settings of the RS485 address

With the menu item “Select interface”, you can use key “2” to switch

between the RS232 and RS485 interfaces.

If the RS485 interface is activated, you can reach the address setting

by pressing key “1”. By pressing key “2”, the address can be set in a

consecutive manner from 1 to 32.

The address then jumps back to 1. The RS485 interface is used to com-

municate with the KACO proLOG, watchDOG or other monitor. If

several inverters are connected to a KACO proLOG, watchDOG or

other monitor each address may only be used once. It is possible to

monitor 31 blueplanet inverters with one KACO proLOG. To connect

the RS485 interface, please contact your installer.

S0 interface pulse rate

The S0 interface is designed as a galvanically isolated transistor

output. This interface is designed according to “DIN 43864 – Current

interface for transmitting pulses from a pulsing meter to a tariff

metering device”.

The S0 interface pulse rate can be chosen in three unit intervals: 500,

1,000 and 2,000 pulses/kWh.

To connect the S0 interface, please contact your installer.

ACTION

Settings are saved only upon exiting configu-

ration mode. If 2 minutes elapse without a key

being pressed, the configuration mode is auto-

matically exited. The configuration mode can also

be immediately exited by pressing both keys. As

a confirmation, “Settings saved” appears on the

display. The settings are now permanently saved

in the blueplanet inverter.

Quick start

The inverter can also be started up without any waiting period for

the purpose of testing or for the purpose of acceptance by your power

supply company.

If the inverter is already feeding into the grid, this menu item is not

available.

If there is insufficient solar generator power, the inverter stops feed-

ing into the grid after a short period of time.

4.5 Level 2 menu – Configuration mode

ACTION

To access configuration mode, press both keys

at the same time. The software version display

appears. Pressing key “1” now switches to the

next menu item and changes can be made in

the respective menu item by pressing key “2”.

The setting value increases each time key “2” is

pressed. If the maximum value has been reached,

the value returns to the minimum setting choice.

Software version

Serial number

Current country

Language selection

Clear the grid-feed counter

Define the initial value of the total yield

Select the interface and

settings of the RS485 address

S0 interface

Quick start

Figure 4.5: Configuration mode menu

Explanation of the individual menu items:

Software version

The current software version is displayed here.

Serial number

Display of the serial number specific to the unit.

Current country

Display of the current country settings.

Language selection

The language of the display interface can be selected here.