5 level 2 menu – configuration mode, Action – KACO blueplanet 1502x User Manual
Page 9
blueplanet Operating Instructions 1502x - 5002x
Page 9
Clear the grid-feed counter
When you clear the grid-feed counter, all counters (Counter yield and
Counter oper. hours) are reset to zero.
To clear the counters, select “Yes” with key “2”, and confirm your
selection by pressing the “1” key. The required code is “2” and is ente-
red using key “2”. By means of an additional confirmation with key
“1”, all counter are cleared. The display “Grid-feed counter cleared!”
confirms that the counters have been cleared.
“Counter yield” and “Counter oper. hours” can be cleared separately from
the other counters. These counters are cleared in the configuration menu
using key 2 and the code 2. ”Counter yield” and “Counter oper. hours” are
always cleared together.
Define the initial value of the total yield
Use this menu setting to define or reset the intial value of the total
yield of the inverter.
Select the Interface and settings of the RS485 address
With the menu item “Select interface”, you can use key “2” to switch
between the RS232 and RS485 interfaces.
If the RS485 interface is activated, you can reach the address setting
by pressing key “1”. By pressing key “2”, the address can be set in a
consecutive manner from 1 to 32.
The address then jumps back to 1. The RS485 interface is used to com-
municate with the KACO proLOG, watchDOG or other monitor. If
several inverters are connected to a KACO proLOG, watchDOG or
other monitor each address may only be used once. It is possible to
monitor 31 blueplanet inverters with one KACO proLOG. To connect
the RS485 interface, please contact your installer.
S0 interface pulse rate
The S0 interface is designed as a galvanically isolated transistor
output. This interface is designed according to “DIN 43864 – Current
interface for transmitting pulses from a pulsing meter to a tariff
metering device”.
The S0 interface pulse rate can be chosen in three unit intervals: 500,
1,000 and 2,000 pulses/kWh.
To connect the S0 interface, please contact your installer.
ACTION
Settings are saved only upon exiting configu-
ration mode. If 2 minutes elapse without a key
being pressed, the configuration mode is auto-
matically exited. The configuration mode can also
be immediately exited by pressing both keys. As
a confirmation, “Settings saved” appears on the
display. The settings are now permanently saved
in the blueplanet inverter.
Quick start
The inverter can also be started up without any waiting period for
the purpose of testing or for the purpose of acceptance by your power
supply company.
If the inverter is already feeding into the grid, this menu item is not
available.
If there is insufficient solar generator power, the inverter stops feed-
ing into the grid after a short period of time.
4.5 Level 2 menu – Configuration mode
ACTION
To access configuration mode, press both keys
at the same time. The software version display
appears. Pressing key “1” now switches to the
next menu item and changes can be made in
the respective menu item by pressing key “2”.
The setting value increases each time key “2” is
pressed. If the maximum value has been reached,
the value returns to the minimum setting choice.
Software version
Serial number
Current country
Language selection
Clear the grid-feed counter
Define the initial value of the total yield
Select the interface and
settings of the RS485 address
S0 interface
Quick start
Figure 4.5: Configuration mode menu
Explanation of the individual menu items:
Software version
The current software version is displayed here.
Serial number
Display of the serial number specific to the unit.
Current country
Display of the current country settings.
Language selection
The language of the display interface can be selected here.
Section 4 ·
Operation