beautypg.com

2 led displays, 3 keys “1” and “2, Important – KACO blueplanet 1502x User Manual

Page 7: Action

background image

blueplanet Operating Instructions 1502x - 5002x

Page 7

4.2 LED displays

The inverter is equipped with three LEDs that give information about

the various operating statuses as follows:

1
2
3

!

ok

Figure 4.2: LED displays

LED (1) (green):

The LED begins to light up when the minimum voltage from a pho-

tovoltaic array is present and goes out again if the array voltage is

lower than the minimum operating voltage. The LED signals that the

inverter is in stand-by mode. If it is illuminated the inverter is ready for

operation or is currently operating.

LED (2) (green):

The LED is lit when the inverter is feeding into the grid.

LED (3) (red):

The LED indicates that the grid-feed was stopped due to a fault.

Wait approx. 10 mins. to see if the fault is temporary. If this is not the

case, notify your authorized electrician.

IMPORTANT

If there is a power failure on the public grid, LED (3) does not light

up. If this happens, all LEDs and the display go out. The inverter

is shut down completely.

The inverter can only resume its normal operation when the public

utility grid is available again.

Check whether the fault in question relates to a general power failure

or whether the circuit breaker between the utility service and the

inverter has tripped. If the circuit breaker has tripped, notify your

authorized technician. If there was a power failure, simply wait until

the fault has been cleared. The system automatically re-starts.

4.3 Keys “1” and “2”

Figure 4.3: blueplanet control keys

Key “1” is used to switch between the various displays for measured

values and data. You use key “2” to configure settings. Here, menu

navigation is divided into two levels. In level 1 (display mode), measu-

red values such as the solar generator voltage can be read. Here, only

key “1” is activated. In level 2 (configuration mode), key “1” is used to

navigate through the individual displays and settings.

ACTION

By pressing key “1” you can choose which measu-

red value is to be displayed.

The menus are continuous, which means that

when you arrive at the last entry in a menu, the

first entry is displayed again the next time key “1”

is pressed (see Figure 4.4).

Section 4 ·

Operation

This manual is related to the following products: