blueplanet Operating Instructions 1502x - 5002x

4.6 Night time start switch

The unit switches off in the evening as nightfall approaches. The

display is no longer shown. In order to retrieve the values from the

current day (daily yield, daily hours of operation and max. grid-feed

power) after the display switches off, the unit can be activated during

the night by pressing the start switch at the bottom of the inverter.

ACTION

To do this, press the “5” switch (see Figure 4.1 – (5)) on the bot-

tom of the inverter for approx. 5 seconds until a display appears.

You can now scroll through the menu and retrieve the saved values. If

over one minute elapses without a key being pressed, the unit switches

off automatically once again.

The “Counter oper. hours “, “Total operating hours”, “Counter yield”,

and “Total yield” data are permanently saved and totaled. This data

remains in memory even if the inverter is switched off for a long time.

The daily yield, daily hours of operation and the max. daily grid-feed

power are available until the following morning and are cleared when

PV generator voltage is present again.

4.7 The RS485 interface

Blueplanet inverters are also equipped with an RS485 interface in

order to enable remote monitoring of your photovoltaic installation.

Several inverters can be monitored over this interface at the same

time. Using the KACO proLOG, watchDOG or other monitoring

device you can receive yield and operating data as well as error mes-

sages by SMS (text message) or e-mail. These monitoring options are

especially recommended for situations where you are unable to check

the functionality of the installation on-site at regular intervals, e.g.

if you live far away from the installation site. Contact your installer if

you wish to integrate remote monitoring into your system.

4.8 Display

Inverters in the blueplanet series are equipped with a back-lit LCD

(see figure 4.1 – (1) which displays measured values and data.

In normal mode, the backlighting is switched off. As soon as you press

one of the keys, the backlighting is activated. If approx. 1 minute

elapses without a key being pressed, it switches off once again.

NOTE

Calculating efficiency by measuring the current and voltage values

leads to unusable results due to the tolerances of the measuring

devices. The sole purpose of these values is to monitor the basic

operation of the system.

IMPORTANT

Due to measuring tolerances, the measured va-

lues may not always correspond to the actual

values. The inverter’s measuring elements have

been selected to ensure maximum solar yields.

Due to these tolerances, the daily yields displayed

on the inverter may deviate from the values on

your supply grid operator’s grid-feed counter by

up to 15 %. At low power operation the sensors

within the unit are not as accurate as when at

higher power therefore long term operation may

cause this high deviation. Under normal opera-

ting conditions this deviation is minimal.