blueplanet Operating Instructions 1502x - 5002x

4.4 Level 1 menu – Display mode

The display menu is shown once the blueplanet inverter starts up.

Measured values and all of the counters are displayed here. Key “1” is

used to navigate through the individual menu items.

Display of inverter type

Generator voltage and current

Grid voltage, current and power

Temperature inside unit

Yield counter

Yield today

Total yield

CO

2

savings (total)

Operating hours counter

Operating hours today

Total operating hours

Display grid errors

Figure 4.4: Display mode menu

Explanation of the individual menu items:

Display of inverter type
Displays the unit name of the inverter (initial setting).

Generator voltage and current
Displays the current voltage and current of the PV array that is con-

nected to the inverter.

Grid voltage, current and power
Displays the current power (W), grid voltage (V), grid frequency (Hz)

and current (A) that the inverter feeds into the grid.

Temperature inside unit
Displays the current heat sink temperature. If the unit becomes too

hot, the unit will reduct power output or switch off.

Yield counter

This counter totals all yields until it is reset.

The customer can

define the time period for this counter, e.g. so that it

acts as a monthly counter. The counter is cleared using

menu level 2, “Clear feed in counter”.

Yield today
The power that has been fed into the grid during the current day. This

value resets to zero each morning.

Total yield
The power that has been fed into the grid since the inverter was

started up. The starting value can be set in menu level “2”.

CO

2

savings (total)

Shows the CO

2

savings of this PV installation compared to the German

electricity mix. The CO

2

savings are calculated from the total yield

counter and can also be cleared with this counter.

Operating hours counter
This counter totals the operating hours until it is reset. The customer

can define the time period for this counter, e.g. ao that it acts as a

monthly counter. The counter is cleared using menu level 2, “Clear

feed in counter”.

Operating hours today
Today’s hours of operation. As soon as the inverter is in stand-by

mode (i.e. when LED (1) lights up), the operating time is added up.

Total operating hours
The operating hours since the inverter was started up. As soon as the

inverter is in standby mode (i.e. when LED (1) lights up), the operating

time is added up.

In addition, all status messages are integrated into this level: As long

as they are present, they are a part of the menu, which means that

they will appear again after you have scrolled through the whole of

level 1. They are automatically

cleared when the DSP shows a fault-free status, or

replaced when the DSP transmits a status that results in

another message.

They only appear in level 1. If they occur while the menu system is in

another level, they are saved and displayed when you return to level

1 as long as they are still present.

Display grid errors
When the function is deactivated, the menu level is run through and

starts by displaying the unit name when key “1” is pressed again.

When the function is activated, the 5 most recent grid faults within

1000 operating hours are displayed.

Pressing key “1” then displays the corresponding fault mes-

sages.

Once the grid faults have been displayed, the menu

level is run through and starts by displaying the

unit name when key “1” is pressed again.