Figure 3.

Index Marks for Actuator Lever Orientation

Construction

Body

Size

Inches

A

(1)

B

(1)

C

ASME Flanges

150

300

600

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

Standard

2

4.88

124 2.19

56

8.25

206

8.50

216 9.25 235

3

6.50

165 3.00

76

10.12 270 11.12 282 11.50 292

4

7.62

194 3.12

79

11.44 290 12.12 308 13.62 346

6

9.00

229 4.00 102 13.62 346 14.38 365 16.50 419

8

9.56

243 5.75 146 13.62 346 15.38 391 17.12 435

10

11.70 297 6.28 160 16.75 425 19.38 492

---

12

13.30 338 7.25 184 20.13 511 22.25 565

---

1.Does not include gaskets

Figure 4.

Required clearances for installation of

Mark V-100 Series Ball Valve Body

M

ark

V-100 S

erieS

C

ontrol

V

alVeS

28

C

A

B

ACTUATOR

MOUNTING STYLE

VALVE OPEN

ACTUATOR POSITION

1

2

3

3

RIGHT

HANDED

LEFT

HANDED

STYLE A

(PDTC)

STYLE B

(PDTO)

STYLE C

(PDTC)

STYLE D

(PDTO)

FLOW

FLOW

FLOW

FLOW

NOTES:

1. Arrow on lever indicates direction of actuator thrust to close valve

2. PDTC - push down to close; PDTO - push down to open

3. Right-hand mounting controls with V notch No. 1;

Left-hand mounting controls with V notch No. 2

4. For 60° operation with push down-to-close action

(extending actuator rod closes valve). Rotate actuator lever clockwise

so that lever index mark is offset 1 spline tooth from valve shaft index

mark for 1/2" through 3/4" (12,7mm through 19,1 mm) valve shafts

and 2 spline teeth from valve shaft index mark for 7/8" (22,2mm) and

larger valve shafts