Jordan Valve Mark V-100 Series Control Valve User Manual
Page 7

-7-
Figure 3.
Index Marks for Actuator Lever Orientation
Construction
Body
Size
Inches
A
(1)
B
(1)
C
ASME Flanges
150
300
600
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
Standard
2
4.88
124 2.19
56
8.25
206
8.50
216 9.25 235
3
6.50
165 3.00
76
10.12 270 11.12 282 11.50 292
4
7.62
194 3.12
79
11.44 290 12.12 308 13.62 346
6
9.00
229 4.00 102 13.62 346 14.38 365 16.50 419
8
9.56
243 5.75 146 13.62 346 15.38 391 17.12 435
10
11.70 297 6.28 160 16.75 425 19.38 492
---
12
13.30 338 7.25 184 20.13 511 22.25 565
---
1.Does not include gaskets
Figure 4.
Required clearances for installation of
Mark V-100 Series Ball Valve Body
M
ark
V-100 S
erieS
C
ontrol
V
alVeS
28
C
A
B
ACTUATOR
MOUNTING STYLE
VALVE OPEN
ACTUATOR POSITION
1
2
3
3
RIGHT
HANDED
LEFT
HANDED
STYLE A
(PDTC)
STYLE B
(PDTO)
STYLE C
(PDTC)
STYLE D
(PDTO)
FLOW
FLOW
FLOW
FLOW
NOTES:
1. Arrow on lever indicates direction of actuator thrust to close valve
2. PDTC - push down to close; PDTO - push down to open
3. Right-hand mounting controls with V notch No. 1;
Left-hand mounting controls with V notch No. 2
4. For 60° operation with push down-to-close action
(extending actuator rod closes valve). Rotate actuator lever clockwise
so that lever index mark is offset 1 spline tooth from valve shaft index
mark for 1/2" through 3/4" (12,7mm through 19,1 mm) valve shafts
and 2 spline teeth from valve shaft index mark for 7/8" (22,2mm) and
larger valve shafts