beautypg.com

Jordan Valve Mark H-900 Series Globe Style Панель управления User Manual

Jordan Valve Control panel

background image

I

nstallatIon

These valves should not be installed in systems that

exceed the ANSI specified temperature and pressure

ratings. Inspect the valves for shipping, damage and

foreign debris when uncrating.

Be sure to use proper hoists with chains or slings

when uncrating and handling these valves. Refer to

Table 1 in the data sheet for valve body weights.

1.

Ensure the pipe is free from welding slag,

chips and other debris by blowing out the line

prior to installation.

2.

Install approved gaskets between the valve

body and the pipeline flanges. For butt weld

ends on the Mark ET Series trim configuration,

remove gaskets and seal rings prior to welding

the body into the pipeline.

3.

For continuous service applications, Jordan

Valve recommends a standard three-valve

maintenance bypass be installed. This

allows isolation of the valve body without

shutting down the pipeline system.

4.

The valve should be positioned on the

line so the flow direction indicator

corresponds to the direction of flow in the

pipeline.

Note: The effectiveness of the pressure-energized
seal will be compromised if return flow exists
where the downstream pressure exceeds up-
stream pressure. The result could be leakage or
damage to the seal.

5.

The valve body should be positioned with

the actuator vertically above it. It

is possible to position the valve with an

orientation below vertical with support

supplied for the actuator. Support for the

actuator is required if there is excessive

vibration in the line, or if the valve body is

positioned more than 45 degrees off

vertical.

I

ntroductIon

Contained in this manual are installation instructions,

maintenance and parts information for the Mark H-900,

H-1500 and H-2500 Series Valve Bodies. Refer to the

appropriate manuals for instructions for the accompa-

nying actuator, positioner and additional accessories.

Only trained or experienced personnel should carry

out the operation and installation of all pressure equip-

ment. If you have any questions regarding the equip-

ment, contact your Jordan Valve representative. A

serial number identifies each Mark H Series valve and

is stamped on the valve body. Please reference this

number when communicating with your Jordan Valve

representative.

I & M Mark H-900, H-1500 and

H-2500 Series

3170 Wasson Road • Cincinnati, OH 45209
Phone 513.533.5600 • Fax 513.871.0105 (f)
[email protected] • www.jordanvalve.com

Installation & Maintenance Instructions for the

Mark H-900, H-1500 and H-2500 Series Globe

Style Control Valves

Warning: Jordan Valve Control Valves must only be used, installed and repaired in accordance with these Installa-
tion & Maintenance Instructions. Observe all applicable public and company codes and regulations. In the event
of leakage or other malfunction, call a qualified service person; continued operation may cause system failure or
a general hazard. Before servicing any valve, disconnect, shut off, or bypass all pressurized fluid. Before disassem-
bling a valve, be sure to release all spring tension.