In Case of Rapid Deceleration Only When KEB Starts

In case of power loss exceeding KEB compensation time

Operation when the multi-function input KEB command is used and the KEB compensation time is

other than 0.0sec.

Drive main circuit
DC bus bar voltage

Drive output
frequency

0

0

KEB Deceleration ratio changeover time (n047)

KEB Deceleration
Time 1

KEB Deceleration
Time 2

Power Loss

OFF

OFF

ON

KEB command

Power Recovery

KEB Starting Voltage
(n048)

During under
voltage detection

OFF

KEB Command

ON

OFF

OFF

ON

OFF

During KEB
detection

OFF

M

u

lti

function

Input

Drive main circuit
DC bus bar voltage

0

KEB Starting Voltage→
(n048)

Power loss

Drive output frequency

UV1 trip occurs and the

motor coasts to a stop.

KEB Compensation time(n143)

ON

0

Note: Without recovery from the power loss within

the KEB compensation time, UV1 trip occurs.