Yaskawa CIMR-V7AM-091 User Manual
Page 13

Date: 02/20/05, Rev: 05-02
Page 13 of 15
TM.V7SW.091
In Case of Rapid Deceleration Only When KEB Starts
In case of power loss exceeding KEB compensation time
Operation when the multi-function input KEB command is used and the KEB compensation time is
other than 0.0sec.
Drive main circuit
DC bus bar voltage
Drive output
frequency
0
0
KEB Deceleration ratio changeover time (n047)
KEB Deceleration
Time 1
KEB Deceleration
Time 2
Power Loss
OFF
OFF
ON
KEB command
Power Recovery
KEB Starting Voltage
(n048)
During under
voltage detection
OFF
KEB Command
ON
OFF
OFF
ON
OFF
During KEB
detection
OFF
M
u
lti
function
Input
Drive main circuit
DC bus bar voltage
0
KEB Starting Voltage→
(n048)
Power loss
↓
Drive output frequency
→
UV1 trip occurs and the
motor coasts to a stop.
KEB Compensation time(n143)
ON
0
Note: Without recovery from the power loss within
the KEB compensation time, UV1 trip occurs.
Operation is performed
according to the status of
main circuit DC bus bar
voltage after tripping.
Multifunc
ti
on
Output
n019or n021acceleration ratio
<2> Depending on set value of KEB
re-acceleration time selection (n146)
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)