Yaskawa High Speed/Torque Status Output Instance 155 (9Bh)
(Details for bytes 10 through 23, Error Alarm Signals 1, 2, and 3)
Bytes 18(Low) and 19(High) -
Error Alarm Signal 1
Bytes 20(Low) and 21(High) -
Error Alarm Signal 2
Bytes 22(Low) and 23(High) -
Error Alarm Signal 3
Bit
Fault
Bit
Fault
Bit
Fault
0h
PUF DC Bus Fuse Open
0h
EF3 External Fault - Terminal 11
0h
CE
Modbus Communication Error
1h
UV1 DC Bus Undervoltage
1h
EF4 External Fault - Terminal 12
1h
BUS EtherNet/IP Bus Fault
2h
UV2 Control Circuit Undervoltage
2h
EF5 External Fault - Terminal 13
2h
Not Used
3h
UV3 Main Circuit Contactor
Answerback
Fault
3h
EF6 External Fault - Terminal 14
3h
Not Used
4h
Not Used
4h
EF7 External Fault - Terminal 15
4h
CF
Out of Control Fault
No Determination of Motor Speed
5h
GF
Ground Fault
5h
EF8 External Fault - Terminal 16
5h
SVE Zero Servo Fault
(Closed loop flux vector only)
6h
OC
Overcurrent Fault
6h
Not Used
6h
EF0 External Communications Fault
7h OV Overvoltage
Fault
7h OS Overspeed Fault
7h
Not Used
8h
OH
Heatsink Over Temperature
Fault
8h
DEV Speed Deviation Fault
8h
Not Used
9h OH1 Drive
Overheat Fault
9h
PGO PG Open, Encoder
(Pulse Generator open circuit)
9h Not
Used
Ah OL1 Motor Overload Fault
Ah
PF
Input Phase Loss Fault
Ah Not Used
Bh OL2 Drive
Overload
Fault Bh
LF
Output
Phase Loss
Bh Not Used
Ch OL3 Overtorque Fault 1 (L6-02)
Ch
Not Used
Ch Not Used
Dh OL4 Overtorque Fault 2 (L6-05)
Dh
OPR Operator Disconnected
Dh Not Used
Eh RR
Not possible in HHP
Eh
ERR EEPROM R/W Error
Eh
Not Used
Fh RH
Not possible in HHP
Fh
Not Used
Fh
Not Used