beautypg.com

Electronic lineshaft with registration – Yaskawa G5 Electronic Line Shaft User Manual

Page 5

background image

Electronic Lineshaft with Registration

Date: 07/01/04, Rev: 04-07

Sheet 5 of 14

TM.G5SW.047


4.3 New Program Parameters

Master PPR

P1-01 = 1024

P1-01 Master

PPR

Q Q Q Q


The number of output pulses per revolution (PPR) from the master encoder.

Ratio Numerator

P1-02 = 1000

P1-02 Ratio

Numerator

Q Q Q Q



Used in conjunction with P1-03 to set up the ratio of the follower. The MOP gear ratio function is multiplied to the P1-
02
/P1-03 ratio to form the final follower gear ratio.

Example: With P1-02 = 4, and P1-03 = 1, the ratio will be 4/1, or 4. With this ratio, for every revolution of the master, the
follower will make four revolutions.

Ratio Denominator

P1-03 = 1000

P1-03 Ratio

Denominator

Q Q Q Q



See P1-02 for description.

Setting Range:

0 to 10,000

Factory Default:

1024 (adjustable while running)

Modbus Address:

0580H

Setting Range:

1 to 10,000

Factory Default:

1000 (adjustable while running)

Modbus Address:

0581H (Serially adjustable while running
without enter command)

Setting Range:

1 to 10,000

Factory Default:

1000 (adjustable while running)

Modbus Address:

0582H (Serially adjustable while running
without enter command)