6.0 New Alarm and Fault Codes

Alarm Display

Name

Description

Corrective Action

FOL_ALM

Following Alarm

Following Alarm

The position error between
the master and follower
exceeded the allowable
amount. (See P1-07, P1-08)

Check for physical
obstruction of the follower
motion.

Fault Display

Name

Description

Corrective Action

FOL_FLT

Following Fault

Following Error

The position error between
the master and follower
exceeded the allowable
amount. (See P1-07, P1-08)

Check for physical
obstruction of the follower
motion.

Encr. Fault

CCW only in ELS

Encoder Direction

Fault

When in Lineshaft mode,
parameter F1-05 must be set
to 0 (CCW direction).

Set F1-05 to 0 (CCW) and
swap wires on the PG-W2
card, terminals 3 and 4.

OPE12

Carrier 2.5, 5, 10

Carrier Frequency

Setting Fault

This software requires the
carrier frequency to be set at
2.5, 5.0, or 10 kHz.

Set C6-01 to 2.5, 5.0, or 10
kHz.




7.0 Changed Defaults of Parameters

Parameter Original

VSG114814

Function

A1-01

Quick Advanced Access

Level

A1-02

Open Loop Vector

Flux Vector

Control Mode

C6-01

15.0 kHz

10.0 kHz

Max Carrier Frequency