Electronic lineshaft with registration, Reg. response 1/2 correction, Mtr rev per cut p3-03 = 1 – Yaskawa G5 Electronic Line Shaft User Manual
Page 10

Electronic Lineshaft with Registration
Date: 07/01/04, Rev: 04-07
Sheet 10 of 14
TM.G5SW.047
Reg. Response
1/2 correction
P3-02 Registration Response Control
Q Q Q Q
This parameter selects the amount of position correction that occurs after each registration mark.
Setting Description
0 No
Correction
1
Full correction. The controller will try and fully correct a registration
error before the next registration mark.
2
1/2 correction. The controller will try and correct ½ the registration
error before the next registration mark.
3
1/3 correction. The controller will try and correct 1/3 the registration
error before the next registration mark.
4
1/4 correction. The controller will try and correct 1/4 the registration
error before the next registration mark.
5
1/5 correction. The controller will try and correct 1/5 the registration
error before the next registration mark.
6
1/6 correction. The controller will try and correct 1/6 the registration
error before the next registration mark.
7
1/7 correction. The controller will try and correct 1/7 the registration
error before the next registration mark.
Mtr Rev per Cut
P3-03 = 1
P3-03 Motor Revolutions Per Cut
Q Q Q Q
This is the number of revolutions that the motor will make per registration mark. The machine must be geared to so that
an even number of motor revolutions occurs between registration marks.
P3-01 = (motor revolutions) / (registration marks)
Example: 2 knife cut of wheel, it would be acceptable to use a 2:1, 4:1, 6:1, 8:1, 10:1, 12:1, 14:1 or 16:1 ratio between the
motor and gear box.
Setting Range:
0 to 7
Factory Default:
2 (adjustable while running)
Modbus Address:
05a1H
Setting Range:
1 to 8
Factory Default:
1
Modbus Address:
05a2H