Power ratings for models 4t0250 – Yaskawa A1000 6-Phase/12-Pulse Input User Manual
Page 39

u
Power Ratings for Models 4T0250o to 4T0675o
Table 9 Power Ratings for Models 4T0250o to 4T0675o
Item
Specification
Drive Model
4T0250o
4T0296o
4T0362o
4T0414o
4T0515o
4T0675o
Maximum Applicable Motor
Capacity kW (HP)
<1>
ND Rating
132
(200)
160
(250)
185
(300)
220
(350)
250
(400)
355
(500-550)
HD Rating
110
(150)
132
(200)
160
(250)
185
(300)
220
(350)
315
(400-450-500)
Input
Input Current (A)
<2>
ND Rating
228
275
317
376
427
603
HD Rating
190
228
275
317
376
511
Rated Voltage
Rated Frequency
6-Phase/12-Pulse: 380 Vac to 480 Vac 50/60 Hz
Note: 6-Phase isolated supply with each of the output windings phase-shifted
by 30 electrical degrees or Hybrid 6-phase topology.
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency Fluctuation
±5%
Input Power (kVA)
ND Rating
227
274
316
375
425
601
HD Rating
189
227
275
316
375
534
Output
Rated Output
Capacity (kVA)
<3>
ND Rating
<4>
191
226
276
316
392
514
HD Rating
165
<5>
198
<5>
232
<5>
282
<4>
343
<4>
461
<4>
Rated Output
Current (A)
ND Rating
<4>
250
296
362
414
515
675
HD Rating
216
<5>
260
<5>
304
<5>
370
<4>
450
<4>
605
<4>
Overload Tolerance
ND Rating: 120% of rated output current for 60 s
HD Rating: 150% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
Carrier Frequency
User adjustable between 1 and 10 kHz
User adjustable between 1 and 5 kHz
Maximum Output Voltage (V)
Three-phase: 380 to 480 Vac (proportional to input voltage)
Maximum Output Frequency (Hz)
400 Hz (user-adjustable)
<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.
<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring conditions,
and power supply impedance. This input current rating is the 3-Phase total input current rating.
Refer to Alternative AC Drive Branch Circuit
Protection on page 85
for the 6-Phase input current rating.
<3> Rated motor capacity is calculated with a rated output voltage of 440 V.
<4> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<5> Carrier frequency can be increased to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.
8 Specifications
YASKAWA TOEP YAIA1U 02A YASKAWA AC Drive – A1000 6-Phase/12-Pulse Input Installation Manual
39