7 troubleshooting – Yaskawa PG-E3 Motor Encoder Feedback User Manual
Page 28

7 Troubleshooting
YASKAWA ELECTRIC TOBP C730600 52C 1000-Series Option PG-E3 Installation Manual
27
Noise interference along the PG
encoder cable is affecting the A
or B pulse.
• Make sure the motor is rotating in the proper direction.
• Investigate problems on the load-side that may be causing the motor to rotate in
the opposite direction.
PG encoder is disconnected or is
not wired properly, or the PG
option or PG encoder are
damaged.
• Rewire the PG encoder and make sure all wiring including shielded wiring is
properly connected
• If the problem continues after cycling power, replace the PG option or the PG
encoder.
Digital Operator Display
Fault Name
oFA00
Non-Compatible Option connected to drive port CN5-A
Cause
Possible Solution
Non-compatible option
connected to drive port CN5-A.
Use only compatible options. Connect PG-E3 to CN5-C. For other option cards,
refer to the Installation Manual for that option card.
Digital Operator Display
Fault Name
oFb00
Non-Compatible Option connected to drive port CN5-B
Cause
Possible Solution
Non-compatible option
connected to drive port CN5-B.
Use only compatible options. Connect PG-E3 to CN5-C. For other option cards,
refer to the Installation Manual for that option card.
Digital Operator Display
Fault Name
oFC01
Option Connection Error at drive port CN5-C
Cause
Possible Solution
Option at drive port CN5-C was
changed during run.
Switch the power off and reconnect the option.
Digital Operator Display
Fault Name
oFC50
PG Encoder Option A/D Conversion Error
Error with the A/D conversion level (VCC level), or A/D conversion timed out.
Cause
Possible Solution
The option card is damaged.
Replace the option card
Digital Operator Display
Fault Name
oFC51
PG Encoder Option Analog Circuit Error
Incorrect signal level (+2.5 V signal)
Cause
Possible Solution
The option card is damaged.
Replace the option card
Digital Operator Display
Fault Name
oS
Overspeed
The motor speed feedback exceeded the F1-08 setting.
Cause
Possible Solution
Overshoot is occurring.
Increase the settings for C5-01 (Speed Control Proportional Gain 1) and reduce
C5-02 (Speed Control Integral Time 1).