6 related parameters – Yaskawa PG-E3 Motor Encoder Feedback User Manual
Page 23

6 Related Parameters
22
YASKAWA ELECTRIC TOBP C730600 52C 1000-Series Option PG-E3 Installation Manual
F1-04
(383)
PG Deviation
Operation
Selection
0: Ramp to stop (decelerates at time set to C1-02)
1: Coast to stop
2: Fast Stop (decelerates at the time set to C1-09)
3: Continue running
NOTICE: Due to potential damage to the motor and
machinery, do not use the "Continue running" setting
except under special circumstances.
CLV
CLV/PM
Range: 0 to 3
F1-05
(384)
PG 1 Rotation
0: Forward = A pulse leads
1: Forward = B pulse leads
CLV
CLV/PM
Range: 0, 1
F1-06
(385)
PG 1 Ratio for
PG Pulse
Monitor
Sets the division ratio for pulses output from the PG
encoder. Set as a three-digit number: x is the first
digit, y is the second digit, and z is the third digit:
When using the PG-E3 option card, the drive
disregards the value set for "x", and uses the formula
1/yz to determine the division rate for the pulse
generator. The setting range is consequently 1/32 to
1.
CLV
CLV/PM
Default: 1
Min: 1
Max: 132
F1-08
(387)
PG Overspeed
Level
Sets the level for detecting overspeed as a percentage
of the maximum output frequency.
CLV
CLV/PM
Default: 115
Min: 0
Max: 120
F1-09
(388)
Overspeed Det.
Time
Sets the time required for the motor to exceed the
level set in F1-08 to trigger a fault.
CLV
CLV/PM
Default: 0.0
Min: 0.0
Max: 2.0
F1-10
(389)
Excessive
Speed
Deviation Det.
Level
Sets the degree of speed deviation to trigger a dEv
fault. Set as a percentage of the maximum output
frequency.
CLV
CLV/PM
Default: 10
Min: 0
Max: 50
F1-11
(38A)
Excessive
Speed
Deviation Det.
Time
Sets the time required a speed deviation situation to
trigger a fault.
CLV
CLV/PM
Default: 0.5
Min: 0.0
Max: 10.0
F1-14
(38D)
PG Disconnect
Det. Time
Sets the time in seconds for PG encoder disconnect to
be detected.
CLV
CLV/PM
Default: 2.0
Min: 0.0
Max: 10.0
F1-18
(3AD)
Reverse
Rotation Det.
for PG 1
0: Disabled
n: Number of times a dv3 situation must be detected
to trigger a fault.
CLV/PM
Default: 10
Min: 0
Max: 10
F1-19
(3AE)
Reverse
Rotation Det.
for PG 1
0: Disabled
n: Number of times a dv4 situation must be detected
to trigger a fault.
CLV/PM
Default: 128
Min: 0
Max: 5000
F1-20
(3B4)
PG 1 Hardware
Disconnect
0: Disabled. No fault if the connection is lost.
1: Enabled. Fault if connection is lost.
CLV
CLV/PM
Default: 1
Range: 0, 1
No.
(Addr. Hex)
Name
Description
Available
Control
Mode
Values