8 specifications, 8specifications – Yaskawa 1000 Series Drive Option - Open Collector Type PG User Manual
Page 34

34
YASKAWA ELECTRIC TOBP C730600 36C 1000-Series Option PG-B3 Installation Manual
8 Specifications
8
Specifications
Table 10 Option Specifications
Items
Description
Model
PG-B3
Compatible
Pulse Generators
Complementary, Open-collector
Single-pulse (A pulse), two-pulse (A, B pulse) or three-pulse (A, B, Z pulse)
H level: 8 to 12 V
L level: 2.0 V max.
PG Encoder Wiring
Length
Complementary: 100 m (328 ft.) maximum
Open-collector: 50 m (164 ft.) maximum
PG Encoder Power
Supply
Output voltage: 12 V
± 5%
Max. Output Current: 200 mA
Compatible Control
Modes
V/f with PG, Closed Loop Vector, Closed Loop Vector for PM motors
Maximum Input
Frequency
50 kHz
Pulse Monitor
Output
Monitor for A, B, and Z pulse output: 24 V max, 30 mA
Open-collector output
PG Encoder
Disconnect
Detection
Software detection
Ambient
Temperature
–10
°C to 50°C (14 °F to 122 °F)
Humidity
95% RH or lower with no condensation
Storage
Temperature
–20
°C to 60°C (–4 °F to 140 °F) allowed for short-term transport of the product
Area of Use
Indoor (free of corrosive gas, airborne particles, etc.)
Altitude
1000 m (3280 ft.) or lower