5 Installation Procedure
YASKAWA ELECTRIC TOBP C730600 36C 1000-Series Option PG-B3 Installation Manual
21
6.
Route the option wiring.
Depending on the drive model, some drives may require routing the wiring through
the side of the front cover to the outside. In these cases, cut out the perforated
openings on the left side of the drive front cover as shown in
-A and leave
no sharp edges to damage wiring.
Route the wiring inside the enclosure as shown in
-B for drives that do not
require routing through the front cover.
Refer to the Peripheral Devices & Options section of the drive Technical Manual for
more information.
Figure 10
Figure 10 Wire Routing Examples
A – Route wires through the openings
provided on the left side of the
front cover.
<1> The drive will not meet NEMA Type 1 requirements if wiring is exposed outside the enclosure.
B – Use the open space provided
inside the drive to route option
wiring.
B
A