6 Related Parameters
28
YASKAWA ELECTRIC TOBP C730600 36C 1000-Series Option PG-B3 Installation Manual
F1-31
(3B0)
PG 2 Pulse
Setting
Sets the pulses to be read from the pulse generator.
V/f w/ PG
CLV
Default: 1024
Min: 0
Max: 60000
F1-32
(3B1)
PG 2 Rotation
0: Forward = A pulse leads
1: Forward = B pulse leads
V/f w/ PG
CLV
Default: 0
Range: 0, 1
F1-33
(3B2)
PG 2 Gear
Teeth 1
Number of gear teeth between the PG and motor.
A gear ratio of 1 will be used if any of these
parameters is set to 0.
V/f w/ PG
Default: 0
Min: 0
Max: 1000
F1-34
(3B3)
PG 2 Gear
Teeth 2
F1-35
(3BE)
PG 2 Division
Ratio for Pulse
Monitor
Sets the division ratio for PG encoder pulse output.
Set as a three-digit number where x is the first digit, y
is the second digit, and z is the third digit:
When only the A pulse is read, this ratio is disabled
and pulses are set as 1/32 : 1.
V/f w/ PG
CLV
Default: 1
Min: 1
Max: 132
F1-37
(3BD)
PG 2 Option
Function
0: A pulse detection
1: AB pulse detection
V/f w/ PG
Default: 0
Range: 0, 1
<1> Varies by drive models.
<2> The number of output pulses for the PG encoder can be calculated with the following formula:
<3> The parameter is available only for the drive connector CN5-C.
<4> Value changes according to the control mode selection in A1-02.
<5> Enabled only when using the V/f with PG control mode.
<6> Depending on the drive series, a second PG encoder (PG 2) may not be possible. Refer to the drive Technical
Manual for the drive in your application.
<7> The parameter is available only for the drive connector CN5-B.
No.
(Addr. Hex)
Name
Description
Control
Mode
Values
Pulses
× 60
F1-31
×
F1-33 (load side)
F1-34 (motor side)
Ratio =
(1 + x)
yz
f
PG
(Hz)
Motor speed at maximum frequency output (min
-1
)
60
× PG rating (p/rev)
=
B3